Service

Dispense chute cover removal

1. Remove top cover.

2. Push chute cover up vertically to slip off

holding tab.

3. After clearing tab, pull chute cover forward

to remove.

Auger motor assembly removal

1. Remove top cover.

2. Remove one thumbnut on rear of motor bracket.

3. Lift motor bracket and motor up, unplug electric

quick disconnects and remove.

Dispense mechanism assembly removal (Fig. 2)

1. Remove top cover.

2. Remove chute cover (see above).

3. Remove auger motor assembly (see above).

4. Remove quick release pins from the ice chutes

and gates, then unplug wires from solenoids.

5. Lift dispense mechanism up and off auger tube.

Auger and auger tube removal (Fig. 3)

1. Remove auger motor and dispense mechanism

assembly (see above).

2. Pull auger upward to clear auger tube.

3. Lift auger tube upward to clear dispenser top.

4. Slide tube and bearing plate through auger

tube gasket.

Dispense wheel removal

1. Remove drain pan assembly and bin access

cover.

2. Remove center thumbnut and threaded rod on

dispense wheel assembly and lift wheel out
front access opening.

solenoid

quick
release
pin

quick
release
pin

gate

ice
chute

Dispense assembly, top view

(RH unit with bath shown)

RH, 8-valve unit

Front View

dispense
chute

drain pan
assembly

valves

chute
cover

top cover

Fig. 1

Fig. 2

2

wheel
motor

baffle

plate

wheel
motor

mounting

plate

dispense
wheel

auger
tube

auger

auger motor
Side View

auger

bearing

plate

stationery
agitator

rotating
agitator

dispenser
Front View

Fig. 3

12