Dispenser troubleshooting guide – Follett VU155K User Manual

Page 14

Advertising
background image

Symptom

Ice does not dispense.

• Auger motor does not run
• Wheel motor does not run

Ice does not dispense.

• Auger motor runs
• Wheel motor runs
• Gate does not open

Ice does not dispense.

• Auger motor does not run
• Wheel motor runs

Ice does not dispense.

• Auger motor runs
• Wheel motor does not run

Warm drinks or soda foaming.

No ice in dispenser.

Possible cause

1. Power switch faulty or in OFF

position; loose connection.

2. Faulty dispense switch.
3. Faulty transformer.
4. Drain pan ajar.
5. Faulty drain pan safety switch.

1. Loose electrical connection.
2. Linkage problem between

solenoid and gate.

3. Faulty solenoid.

1. Loose electrical connection.
2. Faulty auger motor.
3. Faulty run capacitor.

1. Loose electrical connection.
2. Faulty wheel motor.
3. Faulty run capacitor.

1. No ice in storage bin.

2. Water drained out of ice water

bath.

3. Circulating pump not running.

4. CO

2

pressure is set too high.

1. Power switch in OFF position or

faulty.

2. Bin signal switches in OFF

position or faulty.

3. Faulty bin thermostat.
4. Faulty transformer.
5. Icemaker related problem.

6. Faulty or disconnected wiring.

Solution

1. Turn power switch to ON position;

check connections.

2. Replace switch.
3. Replace transformer.
4. Check pan and reseat.
5. Replace switch.

1. Check connections.
2. Check linkage.

3. Replace solenoid.

1. Check connections.
2. Check auger motor.
3. Check run capacitor.

1. Check connections.
2. Check wheel motor.
3. Check capacitor.

1. Fill storage area with ice or check

icemaker operation.

2. Check that ice water bath drain

tube is in fixed upright position.

3. Check pump and PC board for

output.

4. Set CO

2

pressure to 75 psi.

1. Check switch and replace if

necessary.

2. Check switch and replace if

necessary.

3. Replace bin thermostat.
4. Replace transformer.
5. Refer to Icemaker Operation and

Service Manual for diagnosing.

6. Check for power and bin signal on

icemaker PC board.

Dispenser troubleshooting guide

Before calling for service

1. Check that ice is in the dispenser and that congealed cubes are not causing a jam.
2. Check that circuit breaker and switches are in ON position.
3. Check that drain pan, rear lid and top are on securely. If ajar, dispenser will not operate. When the top is off,

auger does not operate, even though the solenoids do (page 17).

4. Check that all drains are clear.

Note: For units equipped with Follett compressed nugget icemaker, see Icemaker Operation and
Service Manual for service and troubleshooting information.