36

Wind sensor

DISPLAY UNIT

Wind Sensor

12 VDC

NMEA port setting: IN/OUT

¬

Connection of wind sensor

Feeding data to RD-30 via the LS-6100

DISPLAY UNIT*

GP-310B

12 VDC

NMEA port setting: IN/OUT
NMEA mix setting: ON

Wind Sensor

RD-30

12/24 VDC

®

*: Navigator-related data not displayed.

¬

4.8 IEC 61162-1 Data

Sentences

The tables below show the data sentences
which can be input to and output from the
LS-6100. The transmission speed for both
input and output is 4800 bps. Data is output
at two-second intervals.

Input data sentences

Sentence Meaning

BWC

Bearing and distance to waypoint

GGA

Global positioning system (GPS)
fix data

GLL Geographic

position

-

latitude/longitude

HDG

Heading, deviation and variation

HDT Heading,

true

MDA Atmospheric

pressure

MTW Water

temperature

Input data sentences (con’t)

Sentence Meaning

MWV

Wind speed and angle

RMA Recommended

minimum specific
LORAN-C data

RMB Recommended

minimum navigation
information

RMC Recommended

minimum specific
GPS/TRANSIT data

VHW

Water speed and
heading

VTG

Course over ground
and ground speed

Output data sentences

Sentence Meaning
DBT (Ver. 1.5)

Depth below
transducer

DPT (Ver. 2.0, Ver. 3.0) Depth
MTW* Water

temperature

RMB* (Ver. 2.0)

Recommended
minimum navigation
information

VHW*

Water speed and
heading

TLL*

Target position, output
by [MARK] key.

* = Available with connection optional

sensors/navaid