6 operator panel, Operator panel, Table 1-7 – FUJITSU SPARC Enterprise Server M5000 User Manual

Page 32: Table 1-8

Advertising
background image

1-20

SPARC Enterprise M4000/M5000 Servers Overview Guide • December 2010

1.3.6

Operator Panel

The operator panel (

FIGURE 1-15

), which is not redundant, displays the system status,

system problem alerts, and location of system faults. It also stores the system
identification and user setting information. For more information on the operator panel
functions, refer to the SPARC Enterprise M4000/M5000 Servers Service Manual.

TABLE 1-7

CPU Types and Maximum Power Consumption on the M4000 Server

*

* M4000 system configuration: CPUM x 2, MEMB x 4, 8GB DIMM x 32, HDD x 2, PCIe x 4, PCI-X x 1, DAT x 1.

CPU Type

Frequency (GHz)

Number

Power
Consumption (W)

Apparent
Power (VA)

Heat Dissipation (KJ/h)

SPARC 64 VI processor

2.15

4

1556

1621

5602

SPARC 64 VII processor

2.4/2.53

4

1656

1725

5962

SPARC 64 VII+ processor

2.66

4

1692

1763

6091

TABLE 1-8

CPU Types and Maximum Power Consumption on the M5000 Server

*

* M5000 system configuration: CPUM x 4, MEMB x 8,8GB DIMM x 64, HDD x 4, PCIe x 8, PCI-X x 1, DAT x 1.

CPU Type

Frequency (GHz)

Number

Power
Consumption (W)

Apparent
Power (VA)

Heat Dissipation (KJ/h)

SPARC 64 VI processor

2.15

8

2998

3123

10793

SPARC 64 VII processor

2.4/ 2.53

8

3198

3331

11513

SPARC 64 VII+ processor

2.66

8

3270

3406

11772

Advertising