eXtended System Control Facility Unit (XSCFU)

The eXtended System Control Facility Unit (XSCFU) is a service processor that
operates and administrates both midrange servers (

FIGURE 1-16

and

FIGURE 1-17

). The

XSCFU diagnoses and starts the entire server, configures domains, offers dynamic
reconfiguration, as well as detects and notifies various failures. The XSCFU enables
standard control and monitoring function through network. Using this function
enables starts, settings, and operation managements of the server from remote
locations.

TABLE 1-10

Status Indicator LED Pattern Summary

LED

POWER

XSCF STANDBY

CHECK

Description of the State

Off

Off

Off

The circuit breaker is switched off.

Off

Off

On

The circuit breaker is switched on.

Off

Blinking

Off

The XSCF is being initialized.

Off

Blinking

On

An error occurred in the XSCF.

Off

On

Off

The XSCF is on standby.
The system is waiting for power-on of the
air conditioning system.

On

On

Off

Warm-up standby processing is in
progress (power-on is delayed).
The power-on sequence is in progress.
The system is in operation.

Blinking

On

Off

The power-off sequence is in progress.
Fan termination is being delayed.