Front load dryers – FRIGIDAIRE FAQE7073K User Manual

Page 2

Advertising
background image

Specifications

subject to change.

Front Load Laundry - Electric Dryers

Frigidaire Affinity

Specifications

subject to change.

of door. Full-length 120 sq. in. opening also acceptable. Allow additional

1" clearance between fronts of units and closed door.

Do NOT install in area exposed to dripping water or outdoor

weather conditions, or where gasoline or other flammables, including

automobiles, are kept or stored.

Floor MUST be solid with 1" maximum slope. Do NOT install on

carpeted surface.

Dryer MUST exhaust to outside of building, NOT into any

concealed space.

Exhaust installation requires minimum 4"-diameter rigid or flexible metal

duct with approved vent hood having swing-out damper(s). Do NOT

use flexible plastic or metal foil duct and use shortest run possible.

Leveling legs supplied to level dryer properly and reduce excessive

noise and vibration.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

Optional Accessories

Dryer Stacking Kit – (PN # 134700600).

15" Classic White Drawer Pedestal – (PN # APWD15W).

15" Classic Black Drawer Pedestal – (PN # APWD15E).

Mobile Home Installation Kit – (PN # 137067200).

Drying Rack – (PN # 137067300).

Front Load Dryer Specifications

Product Shipping Weight (approx.) – 140 Lbs.

An electrical supply with grounded three-prong receptacle is required.

Voltage Rating – 240V / 60 Hz / 30 Amps

Single phase 3- or 4-wire cable, 240 Volt, 60 Hertz AC only electrical

supply with ground required on separate circuit fused on both sides

of line. (Do not use same circuit as washer.)

Connected Load (kW Rating) @ 240 Volts = 5.0 kW

Amps @ 240 Volts = 24 Amps

Dryer MUST employ a 3-conductor NEMA 10-30 type SRDT or

4-conductor NEMA 14-30 type SRDT or ST (as required), rated at

240 volt AC minimum, 30 amp power supply cord marked for

use with clothes dryers (not supplied).

Grounding through neutral link prohibited in specific applications and

certain locales, requiring use of 4-wire system. (For detailed electrical

requirements, refer to Product Installation Guide on web.)

Always consult local and national electric codes.

Can be installed alone, with or without optional 15" Drawer Pedestal,

or stacked above matching Frigidaire® Affinity Washer, which requires

installation of optional Dryer Stacking Kit. (For installation details, refer

to instructions included with optional pedestal or stacking kit or on web.)

Can be built in with matching Frigidaire® Affinity Washer in under-

counter, recessed or closet installation. (Refer to Built-In Installations

on this page for cutout dimensions. For additional installation details,

refer to Product Installation Guide on web.)

Closet installation requires vented door with 2 unobstructed louvered

openings, minimum 60 sq. in. each, located 3" from top and bottom

FRIGIDAIRE®

USA

250 Bobby Jones expressway

Martinez, GA 30907

1-800-FRIGIDAIRe

frigidaire.com

CANADA

5855 Terry Fox Way

Mississauga, ON L5V 3e4

1-800-265-8352

frigidaire.ca

FAQe7073K 06/09

© 2009 electrolux Home Products, Inc.

Printed in the U.S.A.