hold as follows: A smoke detector installed in each separate
sleeping area (in the vicinity, but outside the bedrooms), and heat
or smoke detectors in the living rooms, dining rooms, bedrooms,
kitchens, hallways, attics, furnace rooms, closets, utility and stor-
age rooms, basements and attached garages.”

FOR BEST PROTECTION, WE

RECOMMEND THAT YOU INSTALL A SMOKE

ALARM IN EVERY ROOM.

In addition, we recommend that all smoke alarms be interconnected.

Typical Efficiency
Home (Apartment)

• Install a smoke alarm on the

ceiling or wall closest to the
sleeping area.

Typical Mobile Home
NOTE:
For mobile homes built before 1978, install smoke alarms on

an inside wall between 4 and 12 inches from the ceiling. (Older
mobile homes have little or no insulation in the ceiling.) This is
especially important if the ceiling is unusually hot or cold.

• Install a smoke alarm inside each bedroom and in the hallway

outside each separate sleeping area.

Typical Single-Story Home

• Install a smoke alarm on the ceiling

or wall inside each bedroom and in
the hallway outside each separate
sleeping area. If a bedroom area
hallway is more than 30 feet long,
install a smoke alarm at each end.

If there is a basement:
• Install a smoke alarm on the base-

ment ceiling at the bottom of the
stairwell.

Typical Two-Story or Split Level
Home

• Install a smoke alarm on the ceil-

ing or wall inside each bedroom
and in the hallway outside each
separate sleeping area. If a bed-
room area hallway is more than
30 feet long, install a smoke alarm
at each end.

• Install a smoke alarm at the top of

a first-to-second floor stairwell.

If there is a basement:
• Install a smoke alarm on the basement ceiling at the bottom

of the stairwell.

IMPORTANT SMOKE ALARM

PLACEMENT AND EXCEPTION

INFORMATION

• Install a smoke alarm as close to

the center of the ceiling as possi-
ble. If this is not practical, mount
no closer than 4 inches from a
wall or corner. Also, if local codes
allow, install smoke alarms on
walls, between 4 and 12 inches
from ceiling/wall intersections.

• Install a minimum of two smoke alarms in every home, no mat-

ter how small the home. New construction codes require a min-
imum of two interconnected smoke alarms in newly built
homes.

• Install a smoke alarm in each room

that is divided by a partial wall
(either coming down from the ceil-
ing at least 24 inches, or coming up
from the floor).

24"

STUB WALL

SOFFIT

EFFICIENCY APARTMENT

SLEEPING

AREA

KITCHEN

LIVING

AREA

BEDROOM

BATH

KITCHEN

LIVING ROOM

MOBILE
HOME

BEDROOM

BED-

ROOM

BATH

BASEMENT

FURNACE

ROOOM

KITCHEN

TWO STORY

BEDROOM

BEDROOM

BATH

LIVED-IN

LIVING AREA

KITCHEN

BASEMENT

FURNACE

ATTIC

ROOM

4 IN

(0.1m )

4 IN

(0.1m )

MINIMUM

12 IN

(0.3 m )

MAXIMUM

CEILING

SIDE

WALL

ACCEPTABLE HERE

NEVER HERE

TOP OF DETECTOR

ACCEPTABLE HERE

3

KEY

Smoke Alarm (Ionization)
Photoelectric Smoke Alarm or Ionization Smoke Alarm with

False Alarm Control