Summary of audible/visual notifications, Fixed-word display keypads) – First Alert FA142C User Manual

Page 35

Advertising
background image

– 3 5 –

SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS

(FIXED-WORD DISPLAY KEYPADS)

S O U N D

C A U S E

D I S P L A Y

LOUD, INTERRUPTED*
Keypad & External

FIRE ALARM

FIRE

and

ALARM

are displayed; protection zone in alarm is displayed.

LOUD, CONTINUOUS*
Keypad & External

BURGLARY/AUDIBLE
EMERGENCY ALARM

ALARM

is displayed; protection zone in alarm is also displayed.

Also see "Exit Alarm Warning Displays and Sounds" on page 21.

ONE SHORT BEEP
(not repeated)
Keypad only

a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT

WITH AN OPEN ZONE

c. BYPASS VERIFY

a. Only

READY

is displayed. Green READY indicator (if present) is lit.

b.

NOT READY

is displayed, open protection zone number is displayed.

Green READY indicator (if present) is not lit.

c. The bypassed protection zone numbers are displayed. (One beep for each number

displayed.)

BYPASS

displayed.

ONE SHORT BEEP
(once every 40 seconds)
Keypad only

SYSTEM IS IN TEST MODE

Opened Zone identifications will appear.

ONE BEEP every 40 sec.
Keypad only

a. LOW BATTERY AT XMTR
b. SYST. MAIN BATT. WEAK
c. TROUBLE

a. BAT displayed with ID number of transmitter.
b. BAT displayed with no transmitter ID
c.

CHECK

displayed. Troubled protection zone is displayed.

TWO SHORT BEEPS
Keypad only

ARM AWAY OR MAXIMUM

AWAY

and (if MAXIMUM) I

NSTANT

are displayed.

THREE SHORT BEEPS
Keypad only

a. ARM STAY OR INSTANT
b. ZONE OPENED WHILE SYS-

TEM IS IN CHIME MODE

c. ZONE OPENED WHILE SYS-

TEM IS IN TEST MODE

a.

STAY

and (if INSTANT)

INSTANT

are displayed. Red ARMED indicator is lit.

b.

CHIME

displayed. Pressing

/ READY key will display opened zone.

c. Open protection zone number is displayed.

RAPID BEEPING
Keypad only

MEMORY OF ALARM

FIRE

and/or

ALARM

is displayed; zone in alarm is displayed.

SLOW BEEPING
Keypad only

a. ENTRY DELAY WARNING

b. EXIT DELAY ALERT

(if programmed)

a. No display during delay; Exceeding the delay time without disarming causes alarm.

b.

AWAY

or (if MAXIMUM)

AWAY INSTANT

is displayed. Slow beeps change to fast during

last 5 sec of exit delay.

*If bell is used as external sounder, fire alarm is pulsed ring (see page 29); burglary/audible emergency is steady ring.

Note:

Also see

Other Trouble Displays

and

Total Power Failure

under

TROUBLE CONDITIONS

on pages 27 and 28.

Technical Manuals Online! - http://www.tech-man.com

Advertising