FTLF1217P2xTL Pluggable SFP Product Specification – September 2008

II.

Absolute Maximum Ratings


Parameter Symbol

Min

Typ

Max

Unit

Ref.

Maximum Supply Voltage

Vcc

-0.5

4.0

V

Storage Temperature

T

S

-40 85

°C

Case Operating Temperature

T

A

-40 85

°C

Relative Humidity

RH

0

85

%

1




III.

Electrical Characteristics

(T

A

= -40 to 85

°C, V

CC

= 3.0 to 3.6 Volts)


Parameter Symbol

Min

Typ

Max

Unit

Ref.

Supply Voltage

Vcc

3.0

3.6

V

Supply Current

Icc

300

mA

Transmitter

Input differential impedance

R

in

100

Ω

2

Single ended data input swing

Vin,pp

250 1200

mV

3

Transmit Disable Voltage

V

D

2 Vcc

V

4

Transmit Enable Voltage

V

EN

Vee

Vee+ 0.8

V

Receiver

Single ended data output swing

Vout,pp

250 450 900 mV

5

Data output rise/fall time

≤ 155 Mb/s

t

r

/t

f

0.6 5.0 ns

6

LOS Fault

V

LOS fault

2

Vcc

HOST

V 7

LOS Normal

V

LOS norm

Vee

Vee+0.5

V

7

Power Supply Rejection

PSR

100

mVpp

8

Systematic Jitter Contribution

RX

Δ

SJ

2.0

ns

9

Contributed Duty Cycle Distortion

RX

Δ

DCD

1.0

ns

10

Data Dependent Jitter Contribution

RX

Δ

DDJ

1.2

ns

10

Random Jitter Contribution @ OC-3
and OC-1

RX

Δ

RJ

0.6

ns

9

Random Jitter Contribution @ FE

RX

Δ

RJ

0.76

ns

10


Notes:
1. Non condensing.
2. Connected directly to TX data input pins. AC coupling from pins into driver IC.
3. We recommend <600mV for best EMI performance.
4. Or open circuit.
5. Into 100 ohms differential termination.
6. 10 – 90 %
7. LOS is an open collector output. Should be pulled up with 4.7k – 10kohms on the host board. Normal

operation is logic 0; loss of signal is logic 1. Maximum pull-up voltage is 5.5V.

8. Receiver sensitivity is compliant with power supply sinusoidal modulation of 20 Hz to 1.5 MHz up to

specified value applied through the recommended power supply filtering network.

9. Peak-to-peak measurement for OC-3 SR-0 or OC-1 SR-0 operation measured with a PRBS 2

23

-1 test

pattern.

10. Peak-to-peak measurement based on 4B/5B encoded Fast Ethernet pattern referenced in FDDI PMD

3

Annex A.5

© Finisar Corporation September 13, 2008 Rev. B