Ix. digital diagnostic specifications – Finisar FTLF1217P2XTL User Manual

Page 8

Advertising
background image

FTLF1217P2xTL Pluggable SFP Product Specification – September 2008

© Finisar Corporation September 13, 2008 Rev. B

Page 8


IX. Digital Diagnostic Specifications

FTLF1217P2xTL transceivers have internally calibrated digital diagnostics.

Parameter Symbol

Min

Typ

Max

Units

Ref.

Accuracy

Internally measured transceiver
temperature

DD

Temperature

± 3

ºC

Internally measured transceiver
supply voltage

DD

Voltage

± 100

mV

Measured TX bias current

DD

Bias

± 10

%

1

Measured TX output power

DD

Tx-Power

± 3

dB

Measured RX received average
optical power

DD

Rx-Power

± 3

dB

Dynamic Range for Rated Accuracy

Internally measured transceiver
temperature

DD

Temperature

-40 85 ºC

Internally measured transceiver
supply voltage

DD

Voltage

3.0 3.6 V

Measured TX bias current

DD

Bias

0 70

mA

Measured TX output power

DD

Tx-Power

-22 -13

dBm

Measured RX received average
optical power

DD

Rx-Power

-33 -12

dBm

Max Reporting Range

Internally measured transceiver
temperature

DD

Temperature

-40 125

ºC

Internally measured transceiver
supply voltage

DD

Voltage

2.8 4.0 V

Measured TX bias current

DD

Bias

0 80

mA

Measured TX output power

DD

Tx-Power

-24 -11

dBm

Measured RX received average
optical power

DD

Rx-Power

-35 -10

dBm

Notes:
1. Accuracy of Measured Tx Bias Current is 10% of the actual Bias Current from the driver to the LED.