IV. Optical

Characteristics

(T

OP

= -40 to 85

°C, V

CC

= 3. 00 to 3.60 Volts)

Parameter Symbol

Min

Typ

Max

Unit

Ref.

Transmitter

Output Opt. Power

P

OUT

-20 -15

dBm

1

Optical Wavelength

λ

1280

1380 nm

Spectral Width (FWHM)

σ

175

nm

2

Optical Rise/Fall Time

≤ 155 Mb/s

t

r

/ t

f

0.6 3.0 ns

3

Optical Rise/Fall Time = 200 Mb/s

t

r

/ t

f

1.7

ns

4

Systematic Jitter Contribution

TX

Δ

SJ

1.6

ns

5

Contributed Duty Cycle Distortion

TX

Δ

DCD

1.0

ns

6

Data Dependent Jitter Contribution

TX

Δ

DDJ

0.6

ns

6

Random Jitter Contribution @ OC-3
and OC-1

TX

Δ

RJ

0.6

ns

5

Random Jitter Contribution @ FE

TX

Δ

RJ

0.76

ns

6

Extinction Ratio

ER

10

dB

Receiver

Receiver Sensitivity = 51.8 Mb/s RxSENS

-30 dBm

7

Receiver Sensitivity = 155 Mb/s RxSENS

-30 dBm

7

Receiver Sensitivity = 125 Mb/s RxSENS

-31 dBm

7

Receiver Sensitivity = 200 Mb/s RxSENS

-29 dBm

8

Maximum Average Receiver Power

Rx

MAX

-14

dBm

Optical Center Wavelength

λ

C

1270 1600 nm

LOS De-Assert

LOS

D

-33

dBm

LOS Assert

LOS

A

-45

dBm

LOS Hysteresis

1.5

dB

Notes:
1. Measured average power coupled into 62.5/125um fibre with NA = 0.275. Class 1 eye safety per

FDA/CDRH, IEC, and EN60825-1 safety standards.

2. Also specified to fall within the extrapolated curves in FDDI PMD

3

Figure 9, which allow trade-off

between wavelength, spectral width and transmitter rise/fall times.

3. Unfiltered, 10-90%.
4. Unfiltered, 20-80%.
5. Peak-to-peak measurement for OC-3 SR-0 or OC-1 SR-0 operation measured with a PRBS 2^23-1 test

pattern.

6. Peak-to-peak measurement based on 4B/5B encoded Fast Ethernet pattern referenced in FDDI PMD

3

Annex A.5

7. Specifications are for 50 micro-meter or 62.5 micro-meter fiber.
8. Specifications are for 50 micro-meter or 62.5 micro-meter fiber, based on any valid 8B/10B code

pattern and measured at, or extrapolated to, 10

-15

BER.