User presses or to toggle between Beep On and Beep
Off. Press the key to accept the change and exit the
selection process.

SYSTEM

FAN

MODE

FAN

SPEED

SCHEDULE

BACK

DISPLAY

ENTER

EXIT

Audible Alerts – You can select to have the control beep when entering

menus. When BEEP is displayed press the

key then press

(UP)

or

(DOWN) to toggle between ON and OFF. To accept the change,

press the

key to return to the BEEP screen. Press the

(UP) to go

to the next menu EMHT on Kühl+ models or F C for Kühl models.

Clock Type – You may select between a 12 hr and 24 hr clock. When
1224 is displayed press the

key then press

(UP) or

(DOWN)

to toggle between 12 hr and 24 hr clock. To accept the change, press the

key to return to the 1224 screen. Press the

(UP) to go to the

next menu BEEP.

FRR063

User presses or to toggle the format between 12HR and
24HR display. To exit the selection process and accept the
change, press the key.

SYSTEM

FAN

MODE

FAN

SPEED

SCHEDULE

BACK

DISPLAY

ENTER

EXIT

Emergency Heat – The Kühl+ heat pump models (YS, YM, YL) have
a special feature that is designed to keep the unit providing heat.

When EMHT is displayed press the

key then press

(UP) or

.

F

F

O

d

n

a

N

O

n

e

e

w

t

e

b

e

l

g

g

o

t

o

t

)

N

W

O

D

(

To accept the change, press the

.

n

e

e

r

c

s

T

H

M

E

e

h

t

o

t

n

r

u

t

e

r

o

t

y

e

k

Press the

(UP) to go to the next menu BAND

In the unlikely event of a compressor failure, the heat pump unit may be
switched to operate in the electric heat mode only until repairs can be
made.

.

FRR065

User presses or to toggle between Emergency Heat On
and Emergency Heat Off. Press the key to accept the
change and exit the selection process.

SYSTEM

FAN

MODE

FAN

SPEED

SCHEDULE

BACK

DISPLAY

ENTER

EXIT

FRR067

User presses or to select between AUTO, DM 20, OFF.
Press the key to accept the change and exit the
selection process.

The Dim Auto automatically dims the display and then turns it
off after a period of time. The Dim 20 setting behavior is similar
to AUTO, but prevents the display from turning off. Minimum
brightness is 20%. The Dim Off setting forces the display to run
at full brightness.

SYSTEM

FAN

MODE

FAN

SPEED

SCHEDULE

BACK

DISPLAY

ENTER

EXIT

FRR066

The menu allows the user to adjust the minimum spread
between the Auto Cool set point and the Auto Heat set point.
Press the or key to adjust. The adjust range is 3 to 10.

SYSTEM

FAN

MODE

FAN

SPEED

SCHEDULE

BACK

DISPLAY

ENTER

EXIT

FRR068

User presses or at the same time to toggle between
Fahrenheit or Celsius as their temperature unit of choice.
Press the key to accept the change and exit the selection
process.

SYSTEM

FAN

MODE

FAN

SPEED

SCHEDULE

BACK

DISPLAY

ENTER

EXIT

Auto Changeover ‘Dead Band’ – A buffer Zone between heating and
cooling in which no conditioning occurs. For Kühl+ models with the auto
changeover feature you can select the temperature band between heating
and cooling. From the factory the band is set at 3° F (-16° C). The band is
adjustable from 3° F (-16° C) to 10° F (-12° C). When BAND is displayed
press the key then press (UP) or (DOWN) to toggle between
3 and 10. To accept the change, press the key to return to the BAND
screen. Press the (UP) to go to the next menu F C.

Fahrenheit / Celsius Selection – You may select between displaying
temperature in F or C. When F C is displayed press the

key then

press

(UP) or

(DOWN) to toggle between F and C. To accept the

change, press the

key to return to the F C screen. Press the

(UP) to go to the next menu FRZ.