Add a Remote Thermostat

Remote Thermostat – An external thermostat may be added to the air
conditioner to provide remote temperature sensing and control. The
thermostat interface connector is located on the panel behind the front
grille. To enable the remote thermostat operation, remove the jumper

CAUTION

It is the installer’s responsibility to
ensure that all control wiring
connections are made in accordance
with the installation instructions.

Improper connection of the thermostat
control wiring and/or tampering with
the unit’s internal wiring can void the
equipment warranty.

Failure to follow these instructions can
result in personal injury and damage to
product or other property.

Figure 9

between terminals FP & F2 on the terminal block. Connect the thermostat
using Figure 9 and Table 2 as a guide.

If you connect an external thermostat, all Control Panel buttons will be
disabled with the following exception:

1.

Maintenance commands (double button press & single button
extended press).

2. The

button for Freeze protection.

3. First Button pushed, illuminate the LCD.

4. Changing modes on the remote thermostat will not illuminate the

Control Panel LCD.

Remote Thermostat Selection

Friedrich recommends the use of either the RT4 or RT5. The RT4 is a
digital display thermostat with single speed fan control. The RT5 features
a digital display, two fan speed selection, battery backup and backlight.

For cooling models a single stage cooling thermostat with C, R, G, Y terminals must
be used. For electric heat ‘E’ models a single stage heating and cooling thermostat
with C, R, G, Y, W terminals must be used. For heat pump ‘Y’ models a single
stage heating and cooling thermostat with C, R, G, Y, W, B terminals must be used.

Interface Definitions

Terminal Code

C

GH

GL

B

Y

W

R

Table 2

Wire Connection Function

Common Ground Terminal

Call for High Fan

Call for Low Fan

Call for Heat Pump Reversing Valve

Call for Compressor

Call for Heating

24V Power from Electronic Control to

Wall Thermostat