6. Maintenance

6.1 Adjustment

1) PWR board
Switching regulator frequency is adjusted on PWR board, 20P8181 as below.

Test Point

GND

Rating

Adjuster

TP2

TP1

120.0 kHz ±

10 kHz

VR79

TP5

TP3

120.0 kHz ± 10 kHz

VR80

2) MAIN board
Vcc-c supply voltage to Rate sensor is adjusted by VR96 on MAIN board, 20P8178.

Test Point

GND

Rating

Adjuster

#1 of J20

#2 of J20

5.0 V (Vcc-c)

VR96

6.2 Line voltage check

Line voltages are checked at J3 on the MAIN board.

Line voltage

Test Points on MAIN board

Rating

3.3 V

#4 (+) and #5(-) of J3

3.15 to 3.45 V

5.1 V (5 V)

#1 (+) and #5(-) of J3

4.94 to 5.46 V

6.5 V

#8 (+) and #5(-) of J3

6.2 to 6.8 V

13.5 V (15 V)

#7 (+) and #5(-) of J3

12.5 to 14.4 V

6.3 Jumper setting

Jumper JP1 on the MAIN board is used at factory to set the MAIN board to A or B version.

6.4 LED

CR3 on the MAIN board blinks when the CPU is running.