Appendix 2 Modification on Data Output Circuit

Appendix 1 describes the tentative remedy to prevent U1, U2, and U3 in the heading
output circuit from being damaged.


Following modification (Table below) is the permanent remedy. The connector is

changed from 4 pins to 5 pins for the connection of cable shield.

When installing the unit having the current MAIN board (-55);

1) Connect the cable shield to pin #5 of DATA OUT port.

2) Ground the frame of SC-50/110 securely.

3) Connect the other end of the cable shield to FG when data is IEC61162-1/AD-10

(photo coupler), or SG when data is IEC61162-2 (RS422/485).

4) Ground the frame of the unit connected to SC-50/110 securely.

Before modification

After modification

U1, U2, and U3

MAX3043EUE-T

SN75ALS172DE

CR7 to CR30

RD9.1EB3-T4

1SS226-TE85LF

Connectors (J2 to J7),
DATA1 to DATA 6

231-334/001-000, 4-pin
connector

231-335/001-000,
5-pin connector

Plugs (P2 to P7),
DATA1 to DATA 6

231-304/026-FUR,
4-pin plug

231-305/026-FUR,
5-pin plug

MAIN board

20P8178-33

20P8178-55

Fig.1 Connection on DATA OUT port


Factory-modified sets
SC-50 (SC501): 4403-2637 and after
SC-110 (SC1101): 4404-0360 and after

DATA-H/TD-A
DATA-C/TD-B
SHIFT-H/TD’-A
SHIFT-C/TD’-B
FG

J2 to J7 (DATA OUT port)