3.3 Remote Controller Setting

A remote controller can be set exclusively for use with a specific display unit, in the case of
multiple NavNet display units. Set the remote controller ID mode desired on the menu and
attach appropriate label (supplied with accessories) to the remote controller and display
unit.

1. Press the MENU key followed by the SYSTEM CONFIGURATION and GENERAL

SETUP soft key to show the GENERAL SETUP menu.

Page 2

Page 1

KEY BEEP

ON

LANGUAGE

ENGLISH

RANGE UNIT

nm, kt

TEMPERATURE UNIT

°

F

DEPTH UNIT

ft

WIND UNIT

ft

WIND DATA

APPARENT

SPEED AVERAGING

60 seconds

LOCAL TIME OFFSET

9H 0m

RESET TRIP LOG

NO

TIMEOUT DISPLAY SETTING

15 sec

SAVE MOB KEY FUNCTION

SAVE SHIP POSITION & MOB

WALLPAPER

DEFAULT

LAT/LON DISPLAY

DD˚MM.MMMM'

TD DISPLAY

LORAN C

SPEED

SOG

POSITION DISPLAY

LAT/LON

TIME DISPLAY

24 HOURS

INFRARED REMOTE MODE

A

RANGE & BEARING MODE

RHUMB LINE

BEARING READOUT

MAGNETIC

MAGNETIC VARIATION

AUTO 07.0

°

E

GENERAL SETUP menu

2. Press the NEXT PAGE soft key to show Page 2.
3. Choose INFRARED REMOTE MODE, and press the EDIT soft key to show the I/R

REMOTE MODE window.

I/R REMOTE MODE

A
B
C
D

MODE

A

PRESS '0' AND '2' KEY
TOGETHER TO CHANGE MODE.

Remote controller ID
mode window

I/R REMOTE MODE window

4. Point the remote controller toward the display unit, and then press any key on the

remote controller. Preset mode appears in the remote controller ID mode window.

5. After the confirmation of the remote controller mode on the window appears, press the

[0] and [2] key together on the remote controller to change the controller ID mode setting
among A, B, C and D.

6. Operate the trackball so that the display ID is the same as the controller mode setting.
7. Press the MENU key to close the menu.