Disc ontinued, Fbr211 series – FUJITSU FBR211 User Manual

Page 3

Advertising
background image

3

FBR211 SERIES

n

SPECIFICATIONS

Item

Standard (A or B type)

High sensitive (C or E type)

Contact

Arrangement

1 form C (SPDT)

Material

Gold-overlay silver-palladium / gold-overlay silver

Resistance (initial)

Maximum 100 mΩ (at 0.1 A 6 VDC)

Rating (resistive)

0.5 A 120 VAC or 1 A 28 VDC

Maximum Carrying Current

2 A

Maximum Switching Power

60 VA or 28 W

Max. Switching Voltage*

1

220 VAC or 150 VDC

Maximum Switching Current

1.25 A (AC) or 2 A (DC)

Minimum Switching load*

2

Plastic sealed 1 mA, 1V

(reference)

Flux free 1 mA, 5V

Coil

Nominal Power (at 20°C)

Approximately 450 mW Approximately 200 mW

Operate Power (at 20°C)

Approximately 315 mW maximum Approximately 140 mW maximum

Operating Temperature

–25°C to +55°C (no frost) –25°C to +75°C (no frost)

Operating Humidity

45 to 85%RH

Time Value Operate (at nominal voltage) Maximum 5 ms

Release (at nominal voltage) Maximum 5 ms

Life

Mechanical

5 × 10

6

operations minimum

Electrical

3 × 10

5

operations minimum (at 1 A/ 28 VDC resistive load)

(Refer to the REFERENCE DATA)

1 × 10

5

operations minimum (at 2 A/ 12 VDC resistive load)

1 × 10

5

operations minimum (at 0.5 A/120 VDC resistive load)

Other

Vibration Resistance

10 to 55 Hz (double amplitude of 1.5 mm)

Shock Misoperation

100 m/s

2

(11±

1

ms) 60 m/s

2

(11±

1

ms)

Resistance

Endurance

1,000 m/s

2

(11±

1

ms)

Weight

Approximately 4 g

*

1

If the switching voltage exceeds the rated contact voltage, reduce the current. The current values vary according to the type

of load.

*

2

Values when switching a resistive load at normal room temperature and humidity and in a clean environment. The minimum

switching load varies with the switching frequency and operation environment.

Item

Standard (A or B)

High sensitive (C or E)

Isolation (initial)

Minimum 100 MΩ (at 500VDC)

Dielectric

Strength

500VAC 1 min. (standard)

1,500VAC 1 min. (high isolation coil and contact)

n

INSULATION

Type

Compliance

Contact rating

UL

UL 110

E63615

Flammability: UL 94-V0 (plastics)

0.5A, 120VAC (resistive)

1A, 28VDC (resistive)

CSA

C22.2 No. 14

LR 40304, LR 46016

n

SAFETY STANDARDS

DISC

ONTINUED

(1998)

Advertising