2 troubleshooting, Warning, Fuse replacement – Furuno LCD DISPLAY MU-155C User Manual

Page 26: Battery replacement

Advertising
background image

19

WARNING

Ensure battery polarity is correct.

Wrong polarity may cause the batteries to
explode.

Fuse replacement

The fuse in the power cable protects the equipment from internal fault and overcurrent. If
the fuse blows, find the cause before replacing it. If the fuse blows again after replacement,
request service.

Ship’s power source

Rating of fuse

12 VDC

10A

24 VDC

5A



Battery replacement

The remote controller has two AA batteries.
If the distance from which the remote
controller can be operated has decreased,
change the battery.

Note: Replace all batteries together. Do

not mix old and new batteries.


5.2 Troubleshooting

The table below provides troubleshooting procedures to use when no picture appears. If
you cannot restore the picture, do not attempt to check inside the equipment – there are no
user serviceable parts inside. Refer any work to a qualified technician.

Troubleshooting table

Reason for no picture

Remedy

Ship’s battery voltage too high

Check battery voltage.

Fuse has blown.

Replace fuse.

Cable between MU-155C and external
equipment has loosened.

Refasten cable.

Power cable has loosened.

Refasten cable.


You can confirm which signals are currently input in the SYSTEM menu.

SYSTEM menu

RGB1 RGB2 DVI VIDEO1 VIDEO2 VIDEO3 OSD

SYSTEM

INFRARED REMOTE A A

DEFAULT RESET NO



INFORMATION
RGB1 : 1280x1024 fH: 80KHz fV: 75Hz
RGB2 : 640x480

fH: 31KHz fV: 60Hz

DVI : NO SIGNAL

VIDEO1: NTSC
VIDEO2: PAL
VIDEO3: NO SIGNAL
PROGRAM NO. *****

WARNING

Use the proper fuse.

Use of a wrong fuse can cause fire or
damage to the equipment.

Advertising