4. Pas

s flat washers (M12, supplied), spring washers (M12, supplied) and nuts (M12, supplied)

onto hex. bolts. Fasten by tightening nuts. Do not fasten by tightening the hex. bolts; seal
washers may be damaged.

5. Coat flat washers, spring washers, nuts and exposed parts of bolts with anticorrosive sealant.
6. Prepare ground point in mounting platform (within 300 mm of ground terminal on radar sen-

sor) using M6 x 25 bolt, nut and flat washer (supplied).

7. Run the ground wire (RW-4747, 340 mm, supplied) between the ground terminal and ground

point.

8. Coat ground terminal and ground point with silicone sealant as shown below.

Antenna
unit

Mounting
platform

Silicone
sealant

Flat washer

Rubber mat

Seal washer

Ground
wire

Hex. bolt

Flat washer

Spring washer

Flat washer

Hex. nut

Silicone
sealant

Hex. nut

Weld here.

Silicone
sealant

Ground
wire

antenna
unit

OR

Flat washer

Spring washer

Ground
wire

GROUND

TERMINAL

GROUND

POINT

Hex. nut