Maintaining the fastiron ls hardware, Managing fastiron ls temperature settings, Using the temperature sensor on the fastiron ls – Foundry Networks LS 648 User Manual

Page 43: Hapter, Aintaining, Ls h, Ardware, Anaging, Ls t, Emperature

Advertising
background image

September 2007

© 2007 Foundry Networks, Inc.

5 - 1

Chapter 5

Maintaining the FastIron LS Hardware

This chapter provides instructions for maintaining the FastIron LS.

WARNING: The procedures in this manual are for qualified service personnel.

This chapter contains the following information:

Managing FastIron LS Temperature Settings

This section describes how to display temperature settings on the FastIron LS and how to change the temperature
warning and shutdown levels.

Using the Temperature Sensor on the FastIron LS

The FastIron LS comes with a built-in temperature sensor. The temperature sensor causes the device to generate
a Syslog message and SNMP trap if the temperature exceeds a specified warning level or shutdown level. If the
device’s temperature exceeds the safe threshold (shutdown level), the device will reboot if it stays in the safe
threshold for five minutes.

The software reads the temperature sensor according to the device poll time, which is 60 seconds by default. If
the temperature equals or exceeds the shutdown temperature for five consecutive polls of the temperature by the
software, the software will reboot the device to prevent damage.

Table 5.1: Chapter Contents

Description

See Page

Managing the FastIron LS temperature settings

5-1

Displaying management module CPU usage

5-4

Recommended hardware maintenance schedule

5-4

Installing or replacing a 10-GbE module

5-4

Replacing a fiber optic module (SFP (mini-GBIC) or XFP)

5-5

Cleaning the fiber-optic connectors

5-7

Advertising