Supported media – Foundry Networks LS 648 User Manual

Page 50

Advertising
background image

Foundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide

5 - 8

© 2007 Foundry Networks, Inc.

September 2007

For Temperature, Tx Power, Rx Power, and Tx Bias Current, values are displayed along with one of the following
status values: Low-Alarm, Low-Warn, Normal, High-Warn or High-Alarm. The thresholds that determine these
status values are set by the manufacturer of the XFPs. Table 5.2 describes each of these status values.

NOTE:

This function takes advantage of information stored and supplied by the XFP device. This information is

an optional feature of the Multi-Source Agreement standard defining the XFP interface. Not all component
suppliers have implemented this feature set. In such cases where the XFP device does not supply the information,
a “Not Available” message will be displayed for the specific port that the device is installed

Supported Media

The following media are currently available and supported by FastIron GD and LS devices:

CWDM80

CWDM100

LHA

LHB

1000 Base BXD

1000 Base BXU

100 Base BXD

100 Base BXU

SX2

100FX

100FX-1R

Table 5.2: Status Value Description

Status Value

Description

Low-Alarm

Monitored level has dropped below the "low-alarm" threshold set by the XFP manufacturer.

Low-Warn

Monitored level has dropped below the "low-warn" threshold set by the XFP manufacturer.

Normal

Monitored level is within the "normal" range" set by the XFP manufacturer.

High-Warn

Monitored level has climbed above the "high-warn" threshold set by the XFP manufacturer.

High-Alarm

Monitored level has climbed above the "high-alarm" threshold set by the XFP manufacturer.

FLS648 Switch#show optic 4

Port Temperature Tx Power Rx Power Tx Bias Current

+----+-----------+----------+------------+-------------------+

4/1 30.8242 C -001.8822 dBm -002.5908 dBm 41.790 mA

Normal Normal Normal Normal

4/2 31.7070 C -001.4116 dBm -006.4092 dBm 41.976 mA

Normal Normal Normal Normal

4/3 30.1835 C -000.5794 dBm 0.000 mA

Normal Low-Alarm Normal Low-Alarm

4/4 0.0000 C 0.000 mA

Normal Normal Normal Normal