Troubleshooting, Diagnosing switch indicators, Hapter – Foundry Networks LS 648 User Manual

Page 53: Roubleshooting, Iagnosing, Witch, Ndicators, Chapter 1 troubleshooting

Advertising
background image

September 2007

© 2007 Foundry Networks, Inc.

1 - 1

Chapter 1

Troubleshooting

Diagnosing Switch Indicators

Table 0.1: Troubleshooting Chart

Symptom

Action

Power LED is Off

•

Internal power supply is disconnected.

•

Check connections between the switch, the power cord, and the wall
outlet.

•

Contact Technical Support.

Power LED is Amber

•

Internal power supply has failed. Contact Technical Support.

Diag LED is Amber

•

The switch’s self test has detected a fault.

•

Power cycle the switch to try and clear the condition. If the condition
persists, contact Technical Support.

Link LED is Off

•

Verify that the switch and attached device is powered on.

•

Be sure the cable is plugged into both the switch and corresponding
device.

•

Verify that the proper cable type is used and its length does not
exceed specified limits.

•

Check the adapter on the attached device and cable connections for
possible defects. Replace the defective adapter or cable if
necessary.

(RPS2-EIF) Link LED is Off

•

The port does not have a valid connection to the switch.

•

Check connections between the switch, the power cord, and the wall
outlet.

(RPS2-EIF) Link LED is Amber

•

Primary power supply is active. RPS is on standby.

(RPS2-EIF) Activity LED is Green

•

Primary power supply is off. RPS is now active