EX2100 User’s Guide GEH-6632

Chapter 2 Functional Description

••••

2-19

AUTO

REF

PSS

UEL

AVR

Power

System

Stabilizer

Under

Excitation

Limit

Generator
Terminal
Voltage

Watts

AVR
Setpoint
and
Tracking

(VMAG)

Automatic

Voltage

Regulator

FVR
Track
Value
Setpoint

EXASP

Exciter AVR

Setpoint.

Setpoint

V/Hz Limit;

Reactive

Current

Compen-

sation.

Frequency

VMAG

VMAG

Slip

External
Raise/
Lower

MANUAL

REF

FVR

Field

Voltage

Regulator

FCR

Field

Current

Regulator

Min.

Field Voltage Regulator Setpoint

Firing
Commd
to
Bridge

Field Volts from Bridge Output

FCR Setpoint
(User Input)

Field Current from Bridge DC Shunt

External
Raise/
Lower

Watts

VARs

Reactive
Current

Figure 2-11. Software Block Diagram

The output of the control software is the firing command, which is sent to the bridge
to generate the field current. The individual function blocks are discussed in the
following sections.