Important: If using bottom discharge with roof curb, duct-
work should be attached to the curb prior to installing the
unit. Ductwork dimensions are shown in Roof Curb Installa-
tion Instructions.

Refer to the Roof Curb Installation Instructions for proper curb
installation. Curbing must be installed in compliance with the
National Roofing Contractors Association Manual.

Lower unit carefully onto roof mounting curb. While rigging
unit, center of gravity will cause condenser end to be lower
than supply air end.

To assist in determining rigging requirements, unit weights
are shown as follows:

CG

B

D

A

C

RETURN

SUPPLY

EVAPORATOR COIL

COMPRESSOR 1

COMPRESSOR 2

Y

X

CORNER & CENTER OF GRAVITY LOCATIONS

090/102

120

150

Corner Weight - A

195

230

335

Corner Weight - B

270

330

390

Corner Weight - C

240

280

295

Corner Weight - D

330

405

345

Unit Shipping Weight

1055

1275

1390

Unit Operating Weight

1030

1235

1365

X (Inches)

55

55

47

Y (Inches)

36

36

33.5

DATA

CPG Weights (lbs)

T

O

 

PREVENT

 

SEVERE

 

DAMAGE

 

TO

 

THE

 

BOTTOM

 

OF

 

THE

 

UNIT

DO

 

NOT

 

FORK

 

LIFT

 

UNIT

 

AFTER

 

WOOD

 

STRUTS

 

HAVE

 

BEEN

 

REMOVED

.

CAUTION

Bring condenser end of unit into alignment with the curb. With
condenser end of the unit resting on curb member and using
curb as a fulcrum, lower opposite end of the unit until entire
unit is seated on the curb. When a rectangular cantilever
curb is used, care should be taken to center the unit. Check
for proper alignment and orientation of supply and return
openings with duct.

R

IGGING

R

EMOVAL

T

O

 

PREVENT

 

DAMAGE

 

TO

 

THE

 

UNIT

DO

 

NOT

 

ALLOW

 

CRANE

 

HOOKS

 

AND

 

SPREADER

 

BARS

 

TO

 

REST

 

ON

 

THE

 

ROOF

 

OF

 

THE

 

UNIT

.

CAUTION

Remove spreader bars, lifting cables and other rigging equip-
ment.

ELECTRICAL WIRING

HIGH VOLTAGE !

D

ISCONNECT

 

ALL

 

POWER

 

BEFORE

 

SERVICING

 

OR

 

INSTALLING

 

THIS

 

UNIT

. M

ULTIPLE

 

POWER

 

SOURCES

 

MAY

 

BE

 

PRESENT

. F

AILURE

 

TO

 

DO

 

SO

 

MAY

 

CAUSE

 

PROPERTY

 

DAMAGE

PERSONAL

 

INJURY

 

OR

 

DEATH

.

WARNING

HIGH VOLTAGE !

T

O

 

AVOID

 

PERSONAL

 

INJURY

 

OR

 

DEATH

 

DUE

 

TO

 

ELECTRICAL

 

SHOCK

DO

 

NOT

 

TAMPER

 

WITH

 

FACTORY

 

WIRING

. T

HE

 

INTERNAL

 

POWER

 

AND

 

CONTROL

 

WIRING

 

OF

 

THESE

 

UNITS

 

ARE

 

FACTORY

INSTALLED

 

AND

 

HAVE

 

BEEN

 

THOROUGHLY

 

TEST

 

PRIOR

 

TO

 

SHIPMENT

. C

ONTACT

 

YOUR

 

LOCAL

 

REPRESENTATIVE

 

IF

 

ASSISTANCE

 

IS

 

REQUIRED

.

WARNING

T

O

 

PREVENT

 

DAMAGE

 

TO

 

THE

 

WIRING

PROTECT

 

WIRING

 

FROM

 

SHARP

 

EDGES

. F

OLLOW

 

NATIONAL

 

ELECTRICAL

 

CODE

 

AND

 

ALL

 

LOCAL

 

CODES

 

AND

 

ORDINANCES

. D

O

 

NOT

 

ROUTE

 

WIRES

 

THROUGH

 

REMOVABLE

 

ACCESS

 

PANELS

.

CAUTION