Before you call for service – GE GXSF4OH User Manual

Page 22

Advertising
background image

Problem

Possible Causes

What To Do

Water hard sometimes

Using hot water while the water

• Avoid using hot water during water softening system

softening system is regenerating

recharge because the water heater will refill with hard water.
See Automatic Hard Water Bypass During Recharge section,
page 14.

Control HARDNESS number setting

• Press the MODE button until arrow points to HARDNESS.

too low

Be sure the number shown is the same as the actual grains per
gallon hardness of your water supply. See the Programming
the Control
section if a change in the setting is needed.

Grains of hardness in your water

• Water hardness can change over time, especially in well water.

supply have increased

To check, have the water tested by a water analysis laboratory
or call your local water department. Adjust the HARDNESS
number setting as needed.

Water feels slippery

Absence of hardness minerals

• This is normal. Hardness in water gives it the abrasive feel

after installation of

you may have been accustomed to. The slippery feel is the

water softening system

clean feel of soft water.

Water softening system

Water softening system is a

• Does not use much salt to regenerate—very efficient.

not using any salt

“demand” unit

Possible salt bridge

• See the About the Water Softener System section, page 15.

Possible plugged nozzle and venturi

• See the About the Water Softener System section, page 15.

Water is blue color

Acidic water in copper plumbing

• Have the water tested at once.

after water softening
system was installed

Water softening system

Meter turbine stuck

• See the Service: Manually Initiated Electronics Diagnostics

not regenerating

section for troubleshooting procedures, page 18.

• Call for service.

Sensor wire not plugged into

• See the Service: Manually Initiated Electronics Diagnostics

the control

section for troubleshooting procedures, page 18.

• Call for service.

No power to unit

• Check the circuit breaker or fuses.

Mechanical defect

• Call for service.

Cloudiness on glassware Combination of soft water and

• This is called etching and is permanent. To prevent this

(automatic dishwashers) too much detergent

from happening, use less detergent if you have soft water.
Wash glassware in the shortest cycle that will get them clean.

Excessive/high level

Valve drain hose pinched,

• Any restriction in this drain hose may prevent proper

of water in brine tank

plugged, elevated too high

operation of the nozzle and venturi and reduce or prevent

or otherwise restricted

brine draw during recharge.

Nozzle and venturi dirty, incorrectly

• See the Cleaning the Nozzle and Venturi Assembly section,

assembled or damaged

page 15. With water pressure to the water softening system
off, take the nozzle assembly apart. Inspect, clean and
replace as needed. Any foreign particle(s), scratches, nicks,
etc., in the passages can prevent operation. Be sure holes
in the gasket are centered over holes in the housing.

Before you call for service…

22

Troubleshooting Tips

Advertising