GE GXSF4OH User Manual

Page 23

Advertising
background image

23

Problem

Possible Causes

What To Do

Salty tasting or

Unit not sanitized

•

Complete the Sanitization Procedures on page 13.

brown/yellow colored

•

At completion of recharge cycle (approx. 2 hrs), run water

water after installation

from faucets to purge the salty water.

Low water pressure

Check pressure.
•

Drain height 8

′ or less, pressure should be minimum of 20 psi.

•

Drain height above 8

′, pressure should be minimum of 50 psi.

Restricted drain hose

•

Clean and reconnect hose.

•

Check for kinks in drain line.

Brown/yellow

Unit was idle for a period of time

•

Complete the Sanitization Procedures on page 13.

colored water

Resin beads showing

Cracked distributor

•

Call for service.

up in drinking water
and sink

Sounds you might hear

Running water from the unit

•

This is normal.

into a drain during recharge

Water has air bubbles

Air in system after installation

•

Will go away after it runs for a while.

and is cloudy

Error Code on control

Wiring may have worked loose

•

See page 17 for details.

in the control

•

Unplug transformer.

•

Remove control cover, release clips on side.

•

Check for loose/incorrect wiring connections to electronic
board or switch. Reconnect as required.

•

Reassemble control cover.

•

Plug in Transformer.

•

Wait six minutes for Error Code to reappear.

•

If Error Code reappears, call for service.

GEAppliances.com

Blue light flashing

When power applied

Control needs to be programmed

•

See the Programming the Control section, page 10.

to the system

(a power outage may have occurred)

If “DAYS TO EMPTY”

Low salt level, less than 15 days

•

Fill with salt.

is flashing

•

Reset salt level.

If “Err” in display

Electrical problem with system

•

See page 17 for details.

•

See procedure above, Error code on control.