AZ58H09E – GE Zoneline

®

Premium Series Heat Pump Unit

Specification Created 9/04

390569

GE Appliances

Electrical Wiring
All wiring, including installation of receptacle, must be made in

accordance with local electrical codes and regulations.
Note: Aluminum wiring may pose special problems – consult

a qualified electrician.
Grille Options
Stamped Aluminum Grille – RAG60
Exterior Architectural Louvers Durable Polycarbonate:
RAG61 or RAG64 (Beige)

RAG63 or RAG66 (Bittersweet)

RAG62 or RAG65 (Maple) RAG67 (Extruded Aluminum)
Retrofit Kits:
RAK901L – Wall Case Insulation for use with heat pumps.

RAK40 – Deflector Kit to adapt chassis for use with existing

exterior architectural louvered grilles.
Electrical Connection
230/208 volt units may be plugged into a receptacle. 265 volt

units are provided with a junction box and require direct

connection. (NEC Requires 265V Direct Connection) See

Architects and Engineers Design Data Manual for electrical

connection information including use of sub-base for direct

connected units. Installation must comply with local electrical

codes and regulations.
Power Connection kits required on all Zoneline chassis.

A

C

B

Zoneline RAC Wall Installation

Zoneline Wall Install QSart

Wall Case Dimensions

RAB71 Wall Sleeve

Heavy-gauge galvanized steel, with insulation.

A – 42", B – 13-3/4", C – 16"
RAB77 Wall Sleeve

Molded SMC fiberglass-reinforced polyester compound.

A – 42-1/8", B– 13-7/8", C – 16-1/4

Wall Opening Dimensions

Add 1/4" to A and C dimensions for all cut-out size.

RAB71 16-1/4" Min. H x 42-1/4" Min. W

RAB71 available in 16", 24", 28" and 31" depths

RAB77 16-1/2" Min. H x 42-3/8" Min. W

Maximum Cord Extension (in inches)

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

ge.com or call GE Answer Center

®

service,

800.626.2000.

SIDE

VIEW

Inside

Room

Cabinet

Outside

58

21

Grille

7-1/8

RAB71A = 16
RAB77A = 16-1/4

RAB71A = 20-7/8
RAB77A = 21

Room Air/Installation QSart

265 Volt Sub-Base Connected Units

Sub-Base

Power

Connection Kit

Electric

Heater Watts

Electric

Heat Amps

Min. Circuit

Protection

(Amps)

RAK204E15

RAK5172

2,550

10.3

15

RAK204E20

RAK5202

3,450

13.7

20

RAK204E30

RAK5302

5,000

19.6

30