GE GEH-5304A User Manual

Page 37

Advertising
background image

GEH-5304A

37

Table 15

Air Flow Requirements

For Separately Ventilated Motors

Static Pressure

Inches of Water

A

B

Base

Standard

Enclosed

Speed

Separately

Separately

Frame

RPM

CFM

Ventilated

Ventilated

2512AT, 2513AT

All

380

4.85

6.1

2812AT, 2813AT

All

455

4.8

5.64

A. Standard Separately Ventilated

Air in one CE opening with solid covers on other CE openings.
Standard louvered covers on DE air outlets.

B. Enclosed Separately Ventilated (Air Ducted In and Air Ducted Out)

Air in one CE opening with solid covers on other CE opening.
Air out one DE opening.

Table 16

Renewal Parts

For CD2512AT – CD2813AT Frames

Quick Kit Reference

Frame

Blower Kit

Blower Kit

C-Face Kit **

PY Tach Kit

BC Tach Kit

Series

Less Filter *

With Filter *

8.5” Rabbet

Less Tach

Less Tach

CD25XX

36A171113AAG01

36A171113AAG01

36A172476AAG01

36A171269AAG01

36A171270AAG01

CD28XX

36A171114AAG02

36A171114AAG01

36A167477AAG01

36A171269AAG01

36A171270AAG01

DC PY Tach Only

DC BC-42 Tach Only

DC BC-46 Tach Only

(Fits PY Kit)

(Fits BC Kit)

(Fits BC Kit)

50V/1000 RPM

897A594-002

50V/1000 RPM

897A590-032

50V/1000 RPM

897A591-041

100V/1000 RPM

897A594-001

100V/1000 RPM

897A590-024

100V/1000 RPM

8971591-029

Frame

AN-AC Tach

AN-DC Tach

AN-DC Tach

ANDG240A4***

ANDG240D4***

Series

45/90V/1000 RPM

20V/1000 RPM

50V/1000 RPM

240 PPR

240 PPR

CD25XX

36A167715AAG01

36A167714AAG01

36A167714ADG01

36A167712AAG04

36A167713AAG04

CD28XX

36A167715AAG01

36A167714AAG01

36A167714ADG01

36A167712AAG04

36A167713AAG04

*

Blower motor is 230/460 volt AC, 3 phase, 60 hertz.

***

Requires motor disassembly by qualified service facility to install.

***

Bi-directional, dual output.