Su m m it g as c on ve cti on o ve n – Garland SGM-200S1 User Manual

Page 2

Advertising
background image

Garland Commercial

Industries, LLC

185 East South Street

Freeland, PA 18224

Phone: (570) 636-1000

Fax: (570) 636-3903

Garland Commercial Ranges Ltd

1177 Kamato Road,

Mississauga, Ontario

L4W 1X4 CANADA

Phone: 905-624-0260

Fax: 905-624-5669

Enodis UK LTD

Swallowfield Way,

Hayes, Middlesex

UB3 1DQ ENGLAND

Telephone: 081-561-0433

Fax: 081-848-0041

“D”

TOP VIEW

38"

[965mm]

25-3/8"

[645mm]

54-9/16"

[1386mm]

3/4" N.P.T.

GAS INLET

3/4" REAR

GAS INLET

1" REAR

GAS INLET

7-3/4"

[197mm]

2"

[51mm]

3/4"

[19mm]

(includes

motor)

FLUE: 2-3/8" x 5"

[60mm x 127mm]

38-1/4"

[972mm]

11-1/2"

[292mm]

17-3/4"

[451mm]

1-1/4"

[32mm]

32-1/8"

[816mm]

34"

[864mm]

SINGLE DECK

FRONT VIEW

6-1/4"

[159mm]

DOUBLE DECK

FRONT VIEW

32-1/8"

[816mm]

32-1/8"

[816mm]

1-1/4"

[32mm]

32-1/8"

[816mm]

32-1/8"

[816mm]

14-3/4"

[375mm]

35-7/16"

[900mm]

Form# SGM (06/07)

Su

m

m

it G

as

C

on

ve

cti

on

O

ve

n

Gas Input Ratings shown here are for installations up to

2,000 ft. (610m) above sea level. Specify altitudes over

2,000 ft.

Notes:

1. Standard electrical specifications include motor requirements.

2. (120V units) 115V, 3/4 HP, 2‑speed motor; 1140 and 1725 rpm, 60Hz.

3. (240V units) 200‑240V, 3/4 HP, 2‑speed motor; 1140 and 1725 rpm, 60 Hz

4. A 6 ft. line cord is provided for each 120V deck with a

(NEMA #5‑15P) plug.

5. U. S. Range recommends a separate 15 AMP circuit for each 120V unit.

Model

Int. Dimensions :In (mm)

Ext. Dimensions: In (mm)

Ship Wt

Ship Dim.

W

H

D

W

H **

D (w/motor)

Lbs/kg

Cubic Ft.

SGM‑100S1

29 (736)

24 (610)

24 (610)

38 (965)

57‑1/2 (1461)

41‑1/4 (1048)

510/232

42

SGM‑100D1

29 (736)

24 (610)

28 (711)

38 (965)

57‑1/2 (1461)

44‑1/2 (1130)

510/232

42

SGM‑200S1

29(736)

24(610)

24(610)

38(965)

70‑1/2 (1791)

41‑1/4 (1048)

1024/464

84

SGM‑200D1

29(736)

24(610)

28 (711)

38(965)

70‑1/2 (1791)

44‑1/2 (1130)

1024/464

84

** Height with or without standard casters. Height with low profile casters (double deck) is 68‑1/2" (1740mm).

Models

Input Ratings, Natural & Propane

Operating Pressure *

Electrical Specifications

BTU/hr

kW Equiv.

Gas Inlet

Natural

Propane

120V/1Ph.

240V/1Ph.

Single Deck

60,000

17. 6

(1 )@ 3/4" NPT

4.5" WC

(11 mbar)

10" WC

(25 mbar)

(1)@9.4A

(1)@ 5.2A

Double Deck

120,000

35.2

(1 )@1" NPT

(2)@9.4A

(2)@ 5.2A

*Maximum Pressure 13.8" WC @ 70°F (21°C)
Many local codes exist and it is the responsibility of the owner and installer to comply with those codes.

These appliances are intended for commercial use by professionally trained personnel.

Instillation Notes:

Combustible & Non-Combustible

Wall Clearances:

Sides

1" (25mm)

Back

3" (76mm)

Entry Clearances: In (mm)

Crated

44‑1/2 (1130) Uncrated 32‑1/2 (826)