Graco Inc. Hydra-Clean 1040 User Manual

Page 11

Advertising
background image

11

308-534ą11

Servicing the V–Packings

NOTE: There are two types of packing kits: one is

packings only, the other includes the packings,

rings and retainers.

1. Remove the manifold as outlined in the Pumping

Section.

2. Carefully pull the packing retainer from the manifold.

Examine the o–ring and replace it if it is cut or

damaged.

3. Remove the v–packing and head ring. Pull out the

intermediate retainer ring. Remove the second

v–packing and second head ring.

4. Inspect all parts and replace as necessary.

5. Thoroughly clean the packing cavities and examine

for debris and damage.

6. Lightly grease the packing cavities and then replace

the packings in the following order: head ring,

v–packing, intermediate ring, head ring, v–packing

and packing retainer with the o–ring installed in the

retainer groove.

CAUTION

Install the parts in the proper order and facing

the correct direction. Improperly installed parts

will cause a malfunction.

7. Reassemble the manifold as instructed in Servicing

the Plungers.

Advertising