Graco Inc. Hydra-Clean 1040 User Manual

Page 8

Advertising
background image

8

8ą308-534

SHUTDOWN, FLUSHING AND STORAGE

WARNING

PRESSURE RELIEF PROCEDURE

To reduce the risk of serious bodily injury

,

including fluid injection and splashing in the

eyes, or on the skin, always follow this

procedure whenever you stop spraying for

more than 10 minutes, when shutting down,

and before checking or repairing any part of the

system.

1. Engage the trigger safety latch.

2. Turn the sprayer off.

3. Disconnect the electrical supply.

4. Shut off the water supply.

5. Disengage the trigger safety latch and

trigger the gun to relieve pressure, and then

engage the trigger safety latch again.

6. Before long–term (overnight) storage,

disconnect the water supply and

disconnect the electricity.

1. If the pressure washer will be exposed to freezing

temperatures, drain all water out of the pump. If it

must be stored in freezing temperatures, flush the

unit with a 50% anti–freeze solution. Relieve

pressure. Flush the pressure washer before using it

again to remove the anti–freeze.

CAUTION

If water does freeze in the pressure washer ,

thaw it in a warm room before trying to start it.

DO NOT pour hot water on or into the pump; it

may crack the ceramic plungers!

2. After each use, wipe all surfaces of the pressure

washer with a clean, damp cloth.

3. Perform the appropriate maintenance. See the

maintenance chart.

MAINTENANCE

Observing regular maintenance intervals helps ensure

that you get maximum performance and life from the

pressure washer.

There is a break–in period for the pump. After changing

the oil initially, the interval between required changes is

longer.

WARNING

To reduce the risk of serious bodily injury

,

including fluid injection, splashing in the eyes or

on the skin or injury from moving parts, always

follow the

Pressure Relief Procedure

Warning before proceeding.

Interval
Daily

After first 50

hours of

operation
Each 500 hours

of operation or 6

months

What to do
Clean water inlet screen and

filter. Check pump oil level. Fill

as necessary.
Change pump break–in oil. Use

SAE 20 or 30 non–detergent oil.

Change pump oil. Use SAE 20

or 30 non–detergent oil.

Advertising