Troubleshooting chart – Graco Inc. Hydra-Clean 1040 User Manual

Page 9

Advertising
background image

9

308-534ą9

TROUBLESHOOTING CHART

WARNING

To reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, or

injury from moving parts, always follow the

Pressure Relief Procedure Warning before proceeding.

PROBLEM

CAUSE

SOLUTION

Low pressure and/or

pump runs rough

Replace with tip of proper size.
Clean. Check more frequently.
Check filter. Replace packings. See PUMP SERVICE.

Check water flow rate to pump. Unit must have a

minimum 55 gallon float valve controlled water holding

tank.
Tighten or replace.
Clean inlet and discharge valve assemblies. Check

filter.

Check garden hose, may be collapsed or kinked.
Replace worn valves.
Replace high pressure hose.

Worn or wrong size tip.
Inlet filter clogged.
Worn packings, abrasives in water or

natural wear.
Inadequate water supply.

Belt slippage.
Fouled or dirty inlet or discharge valves.

Even a small particle can cause the valve

to stick.
Restricted inlet.
Worn inlet or discharge valves.
Leaking high pressure hose.

Water leakage from

under pump manifold

Install new packings. See PUMP SERVICE.

Worn packings.

Water in pump

Humid air condensing inside crankcase.
Worn packings.
Oil seals leaking.

Change oil as specified in MAINTENANCE.
Install new packings. See PUMP SERVICE.
Install new oil seals. See PUMP SERVICE.

Frequent or

premature failure of

the packings

Scored, damaged or worn plungers.
Abrasive material in the fluid being pumped.
Inlet water temperature too high.
Overpressurizing pump.

Excessive pressure due to partially plugged

or damaged tip.
Pump running too long without spraying.

Running pump dry.

Install new plungers. See PUMP SERVICE.
Install proper filtration on pump inlet plumbing.
Check water temperature; may not exceed 160

_

F.

Do not modify any factory–set adjustments. See

EQUIPMENT MISUSE HAZARD.
Clean or replace tip. See Installing and Changing Spray

Tips.
Never run pump more than 10 minutes without

spraying.
Do not run pump without water.

Strong surging at the

inlet and low pressure

on the discharge side

Foreign particles in the inlet or discharge

valve or worn inlet and/or discharge

valves.

Clean or replace valves. See PUMP SERVICE.

Unit will not start

Unit not plugged in.
Electrical service off/GFCI activated.
Thermal overload has tripped.

Check power cord.
Check fuse/circuit breaker. Check for proper grounding.
Press reset button on motor for 1 phase units. Press

stop button on the motor starter for 3 phase units.

Advertising