GE WBVH6240 User Manual

Page 52

Advertising
background image

– 52 –

T e s t

Mode

Press

Displays

Exit

t01

Start/
Pause

Display defi nes model id (01-03). Always displays"---" when control
board replaced. Proper model must be set when control board
replaced. Rotate knob until desired selection is displayed (01-03),
then press and hold Start/Pause until beep.

Press Power.
Returns to t01

t02

Start/
Pause

Displays the most recent error code. (E00=none) Repeat pressing
Start/Pause to display up to previous 10 error codes. Press and hold
Start/Pause to clear all error codes. (Will then display E00.)

Press Power.
Returns to t02

t03

Start/
Pause

Displays software revision numbers. Press Start/Pause to alternate
between COD (Control software version), EE (eeprom version), and
InV (Inverter software version).

Press Power.
Returns to t03

t04

Start/
Pause

Displays and tests loops on lighting of LED'S and cycle lights.
Buttons beep when pressed.

Press Power.
Returns to t04

t05

Start/
Pause

Displays P and operates pump for 60 seconds, then returns to t05.

Press Power.
Returns to t05

t06

Start/
Pause

Water level control test. Pump runs and displays E at start (no
water in tub). Press Start/Pause to advance. Water valve begins fi ll.
Displays F when reaches FOAM level. Displays nl when reaches
MAIN level, and briefl y displays oF when reaches overfl ow level,
then pumps water out. Displays E when empty.

Press Power.
Pump runs.
Returns to t06

t07

Start/
Pause

Water heater/thermistor test. (Note: Main level switch must be
functional.) Fills with water to main level, then operates heater
for up to 5 minutes. Displays temperature of water, as heated, in
degrees F. After 5 minutes, water pumps out, then returns to t07.

Press Power.
Pump runs.
Returns to t07

t08

Start/
Pause

Water valve test. Displays hOt and pump runs. Fills with hot water.
Maximum level is main level switch setting. Pumps out water and
returns to t08.

Press Power.
Pump runs.
Returns to t08

t09

Start/
Pause

Water valve test. Displays Cld and pump runs. Fills with cold water.
Maximum level is main level switch setting. Pumps out water and
returns to t09.

Press Power.
Pump runs.
Returns to t09

t10

Start/
Pause

Tumble test. Displays tt. Wash basket spins in one direction for 5
seconds, pauses, then spins in the opposite direction for 5 seconds.
Repeats until exit initiated. (Note: Beginning direction is random.)

Press Power.
Pump runs.
Returns to t10

t11

Start/
Pause

Spin speed-low spin/high spin test. Display shows rpm. Pump runs,
displays 0, then wash basket ramps to 400 rpm. Press Start/Pause
a second time to ramp to 1000 rpm. (May display 999 or 0 for 1000
rpm.) Then motor is unpowered, displays 0, pump runs, and returns
to t11.

Press Power.
Pump runs.
Returns to t11

t12

Start/
Pause

Dispenser motor/mechanism test. Press Start/Pause to advance.
Displays Pdt and fi lls via prewash compartment. Displays
ddt and fi lls via wash compartment. Displays bdt and fi lls via
bleach compartment. Displays Fdt and fi lls via fabric softener
compartment. (Note: If main level reached during test, dispenser
operation stops, pump runs, and returns to t12.)

Press Power.
Pump runs.
Returns to t12

t13

Start/
Pause

EOL test sequence. Not used for service.

Press Power.
Returns to t13

t14

Start/
Pause

Spin speed ramp up test. Display shows rpm. Pump runs, displays
0, then wash basket ramps to 100 rpm, pauses, ramps to 350 rpm,
pauses, then ramps to and holds at 1000 rpm. (May display 999 or
0 for 1000 rpm.)

Press Power.
Pump runs.
Returns to t14

Advertising