DIMENSIONS
Rev B
DIMENSIONS
Performance Specifications
1
,
2
Minimum
Maximum
Average
Permeate Flow Rate
0.33 gals/min (1.25 Lpm)
0.75 gals/min (2.84 Lpm)
0.50 gals/min (1.89 Lpm)
TDS Rejection (NaCl)
3
90%
99%
93%
Minimum and Maximum Operating Conditions
Condition
Minimum
Maximum
Inlet Pressure
40 psi (2.76 bar)
80 psi (5.52 bar)
Inlet Temperature
40
°F (4.44°C)
100
°F (37.78°C)
Inlet TDS
50 mg/L
2,000 mg/L
Inlet Hardness
0 mg/L (0 grain)
171 mg/L (10 grain)
Inlet Chlorine
0 mg/L
1.0 mg/L
Inlet Iron
0 mg/L
0.1 mg/L
Inlet Manganese
0 mg/L
0.05 mg/L
Inlet pH
4
10
Inlet Turbidity
0
1 NTU
1. Based on 50 psi (3.44 bar), 77
°F (25°C), 750 mg/L NaCl, 23.7% Recovery
2. System is designed for use on potable water systems only.
3. Specifications based on GE Osmonics testing data. For complete WQA test results to ANSI/NSF 58 standard,
see the Merlin Performance Data Sheet P/N 1263717.