DIMENSIONS

Rev B

DIMENSIONS

Performance Specifications

1

,

2

Minimum

Maximum

Average

Permeate Flow Rate

0.33 gals/min (1.25 Lpm)

0.75 gals/min (2.84 Lpm)

0.50 gals/min (1.89 Lpm)

TDS Rejection (NaCl)

3

90%

99%

93%

Minimum and Maximum Operating Conditions
Condition

Minimum

Maximum

Inlet Pressure

40 psi (2.76 bar)

80 psi (5.52 bar)

Inlet Temperature

40

°F (4.44°C)

100

°F (37.78°C)

Inlet TDS

50 mg/L

2,000 mg/L

Inlet Hardness

0 mg/L (0 grain)

171 mg/L (10 grain)

Inlet Chlorine

0 mg/L

1.0 mg/L

Inlet Iron

0 mg/L

0.1 mg/L

Inlet Manganese

0 mg/L

0.05 mg/L

Inlet pH

4

10

Inlet Turbidity

0

1 NTU

1. Based on 50 psi (3.44 bar), 77

°F (25°C), 750 mg/L NaCl, 23.7% Recovery

2. System is designed for use on potable water systems only.
3. Specifications based on GE Osmonics testing data. For complete WQA test results to ANSI/NSF 58 standard,

see the Merlin Performance Data Sheet P/N 1263717.