Test 5- wire continuity – Generac Power Systems Quietpact 75 User Manual

Page 42

Advertising
background image

S

Se

ec

cttiio

on

n 7

7

D

DIIA

AG

GN

NO

OS

ST

TIIC

C T

TE

ES

ST

TS

S

PROCEDURE:

1. Disconnect Wire 4 from the Voltage Regulator (VR). (Third ter-

minal from the top of VR).

2. Connect a jumper wire to Wire 4 and to the 12 volt fused battery

positive supply Wire 15 (Wire 15 located at fuse (F1) holder).

3. Set the VOM to measure AC voltage.

4. Disconnect Wire 2 from the DPE breaker (CB3) and connect

one test lead to that wire. Disconnect Wire 6 from the Voltage
Regulator and connect the other test lead to that wire. Start the
generator and measure the AC voltage. It should be above 60
volts. Record the results and stop the generator.

5. Re-connect Wire 2 to the DPE Circuit Breaker (CB3) and re-

connect Wire 6 to the Voltage Regulator.

6. Disconnect Wire 11 from the Voltage Regulator (VR) and con-

nect one test lead to that wire. Disconnect Wire 22 from the
Voltage Regulator and connect the other test lead to that wire.
Start the generator and measure the AC voltage. It should be
above 60 volts. Record the results and stop the generator.

7. Re-connect Wire 11 and Wire 22 to the Voltage Regulator.

8. Remove the jumper wire between Wire 4 and 12 volt supply.

9. Set the VOM to measure DC amps.

10. Connect one test lead to the 12 volt fused battery supply Wire

15, and connect the other test lead to Wire 4 (should still be
disconnected from the VR).

11. Start the generator. Measure the DC current. Record the rotor

amp draw.

12. Stop the generator. Re-connect Wire 4 to the Voltage

Regulator.

RESULTS:
Proceed to “TEST 4 RESULTS” (top of page 40).
Match all results to corresponding column in the
chart. The column letter refers to the Problem 4 flow
charts on pages 28 and 29.

TEST 5- WIRE CONTINUITY

DISCUSSION:
The Voltage Regulator receives unregulated alternat-
ing current from the Stator Excitation Winding via
Wires 2, 6 and 2A. It also receives voltage sensing
from the Stator AC Power Windings via Wires 11 and
22. The regulator rectifies the AC from the Excitation
Winding and, based on the sensing signals, regulates
that DC current flow to the Rotor. The rectified and
regulated current flow is delivered to the Rotor
Brushes via Wires 4 (+) and 0 (-). This test will verify
the integrity of Wires 0 and 2A.

PROCEDURE:

1. Set a VOM to its “Rx1” scale.

2. Remove Wire 0 from the Voltage Regulator, fourth terminal from

the top (identified by a negative (-) sign next to terminal).

3. Connect one test lead to Wire 0 and the other test lead to a

clean frame ground. The meter should read continuity.

4. Disconnect Wire 2A from the Voltage Regulator, sixth terminal

from the top. Disconnect the other end of this wire from the

Page 40

T

TE

ES

ST

T 4

4 R

RE

ES

SU

UL

LT

TS

S

A

A

B

B

C

C

D

D

E

E

F

F

G

G

VOLTAGE RESULTS

ABOVE

ABOVE

BELOW

ZERO OR

BELOW

BELOW

ABOVE

WIRE 2 & 6

60 VAC

60 VAC

60 VAC

RESIDUAL

60 VAC

60 VAC

60 VAC

EXCITATION WINDING

VOLTAGE

(5-12 VAC)

VOLTAGE RESULTS

ABOVE

BELOW

ABOVE

ZERO OR

BELOW

BELOW

ABOVE

WIRE 11 & 22

60 VAC

60 VAC

60 VAC

RESIDUAL

60 VAC

60 VAC

60 VAC

POWER WINDING

VOLTAGE

SENSE LEADS

(5-12 VAC)

ROTOR AMP DRAW

.85 A

.85 A

.85 A

ZERO

≥1.2 A

.85 A

ZERO

QP55

± 20%

± 20%

± 20%

CURRENT

± 20%

CURRENT

(MODEL 4702/4703)

DRAW

DRAW

ROTOR AMP DRAW

1.2 A

1.2 A

1.2 A

ZERO

≥1.5 A

1.2 A

ZERO

QP65

± 20%

± 20%

± 20%

CURRENT

± 20%

CURRENT

(MODEL 4704/4705)

DRAW

DRAW

ROTOR AMP DRAW

.87-.79 A

.87-.79 A

.87-.79 A

ZERO

≥1.2 A

.87-.79 A

ZERO

QP75

± 20%

± 20%

± 20%

CURRENT

± 20%

CURRENT

(MODEL 4706/4707)

DRAW

DRAW

((M

MA

AT

TC

CH

H R

RE

ES

SU

UL

LT

TS

S W

WIIT

TH

H L

LE

ET

TT

TE

ER

R A

AN

ND

D R

RE

EF

FE

ER

R T

TO

O F

FL

LO

OW

W C

CH

HA

AR

RT

T –

– P

Prro

ob

blle

em

m 2

2 o

on

n P

Pa

ag

ge

es

s 2

28

8 &

& 2

29

9))

Advertising
This manual is related to the following products: