4.3

CHANGING THE ENGINE OIL

4.3.1 ENGINE OIL RECOMMENDATIONS

Use oil of American Petroleum Institute (API) Service
Class SG, SH or SJ. Use all season SAE 5W-30
Synthetic oil. Organic break-in oil is required before
using synthetic oil.

NOTE:

The unit is supplied with “break-in” oil. See the
“Break-in Procedure,” Section 3.1, for the first
required oil change.

Any attempt to crank or start the engine before
it has been properly serviced with the recom-
mended oil may result in an engine failure.

4.3.2 OIL CHANGE PROCEDURE

To change the oil, proceed as follows:

1. Run the engine until it is thoroughly warmed up

then shut OFF the engine.

2. Immediately after the engine shuts OFF, pull the

oil drain hose (Figure 4.4) free of its retaining
clip. Remove the cap from the hose and drain the
oil into a suitable container.

3. After the oil has drained, replace the cap onto the

end of the oil drain hose. Retain the hose in the clip.

4. Refill with the proper recommended oil (see

Section 4.3.1). See Section 1.5.2 for oil capaci-
ties.

Figure 4.4 – Oil Drain Hose and Filter

4.4

CHANGING THE OIL FILTER

Change the engine oil filter as follows:

1. With the oil drained, remove the old oil filter by

turning it counterclockwise.

2. Apply a light coating of clean engine oil to the gas-

ket of the new filter. See Section 1.5.1 for recom-
mended filter.

3. Screw the new filter on by hand until its gasket

lightly contacts the oil filter adapter. Then, tight-
en the filter an additional 3/4 to one turn (Figure
4.4).

4. Refill with the proper recommended oil (see

Section 4.3.1). See Section 1.5.2 for oil capaci-
ties.

5. Start the engine and check for leaks.

4.5

CHANGING THE ENGINE
AIR CLEANER

4.5.1 7 KW, 12 KW AND 15 KW

GENERATORS

See Figures 1.1 and 1.2, for the location of your air
cleaner. Use the following procedure (Figure 4.6):

1. Turn the two screws counterclockwise to loosen.
2. Remove the cover and air filter.
3. Wipe away dust or debris from inside of the air

box and around edges.

4. Install the new air cleaner into the air box.
5. Install the cover. Turn the two cover screws clock-

wise to tighten.

See the “Service Schedule,” Section 4.13, for air
cleaner maintenance. See Section 1.5.1 for air filter
replacement part number.

Figure 4.6 — 7 kW, Engine Air Cleaner Location

Air Cleaner

Fuel

Regulator

‹

Oil Filter

Oil
Drain
Hose

Low Oil Switch

High Temp Switch

Loose

n

‹

!

‹

Section 4 — Maintenance

Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators

Advertising