Performance data sheet, Warning – GE GNSV70RBL User Manual

Page 4

Advertising
background image

Performance Data Sheet.

SmartWater Filtration System GNSV70RBL and GNSV75RWW
Using Filter FQSVF

■ This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated

substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system,
as specified in NSF/ANSI 42 and 53.

■ Actual performance may vary with local water conditions.

WARNING:

Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection

before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

Standard No. 42: Aesthetic Effects

USEPA

Influent

Influent

Effluent

% Reduction

Min. Required

Parameter

MCL

Challenge Concentration

Average

Average

Maximum

Average

Minimum

Reduction

Chlorine

2.0 mg/L + 10%

2.00 mg/L

<0.05 mg/L

<0.05 mg/L

97.50%

97.50%

>50%

T & O

Particulate**

≥ 10000 particles

4100000 #/mL

76500 #/mL

110000 #/mL

98.10%

97.30%

>85%

Standard No. 53: Health Effects

Turbidity

0.5 NTU***

11 + 1 NTU***

11.0 NTU

0.1 NTU

0.1 NTU

98.80%

98.20%

0.5 NTU

Cysts

99.95% red.

Min. 50000L

140000 #/L

1 #/L

1 #/L

>99.99%

>99.99%

99.95%

Asbestos

99% red.

280 MF/L

<0.17 MF/L

<0.17 MF/L

>99.00%

>99.00%

99%

Lead,

0.010 mg/L

0.15 mg/L + 10%

0.150 mg/L

<0.001 mg/L

<0.001 mg/L

>99.30%

>99.30%

0.010 mg/L

pH 6.5
Lead,

0.010 mg/L

0.15 mg/L + 10%

0.140 mg/L

<0.001 mg/L

<0.001 mg/L

>99.30%

>99.30%

0.010 mg/L

pH 8.5
Mercury,

0.002 mg/L

0.006 mg/L ± 10%

0.0065 mg/L

<0.0002 mg/L

<0.0002 mg/L

96.60%

>96.70%

0.002 mg/L

pH 6.5
Mercury,

0.002 mg/L

0.006 mg/L ± 10%

0.0059 mg/L

<0.0002 mg/L

<0.0002 mg/L

96.60%

96.70%

0.002 mg/L

pH 8.5
Lindane

0.0002 mg/L

0.002 mg/L ± 10%

0.00193 mg/L

<0.00002 mg/L

0.00005 mg/L

>98.80%

98.80%

0.0002 mg/L

Benzene

0.001 mg/L

0.015 mg/L ± 10%

0.014 mg/L

<0.0005 mg/L

<0.0005 mg/L

>96.40%

>96.40%

0.005 mg/L

Atrazine

0.003 mg/L

0.009 mg/L ± 10%

0.00873 mg/L

<0.0005 mg/L

<0.0005 mg/L

>94.10%

>94.10%

0.003 mg/L

VOC Reduction

Chloroform

0.080 mg/L

0.300 ± 10%

0.340 mg/L

0.00098 mg/L

0.00620 mg/L

97.90%

98.20%

95%

*Tested using a flow rate of 0.60 gpm (2.27 l/min); pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C)
**Measurement in particles/mL. Particles used were 0.5–1 microns.
***NTU—Nephelometric Turbidity Units
Operating Specifications
Capacity: certified for up to 160 gallons (605 l); up to six months
Pressure requirement: 35–120 psi (2.8–8.2 bar)
Temperature: 33–100°F (0.6–38°C)
Flow rate: 0.60 gpm (2.27 l/min)

4

Replacement Filter Canisters/Estimated Replacement Costs
FQSVF—Replacement filter canister $35–40
For replacement parts, call toll-free 800.626.2002 (U.S.), 800.663.6060 (Canada–English), 800.361.3869 (Canada–French)

IOWA RESIDENTS ONLY:

Store or Seller’s Name

Address

City

State

Zip

Telephone

Seller’s signature

Customer’s signature

Date

Maximum Permissible

Product Water

Concentration

State of California

Department of Health Services

Water Treatment Device

Certificate Number

Date Issued: February 9, 2009

Trademark/Model Designation

Replacement Element(s)

1601

04 -

GXSV65 F

FQSVF

GQSV65 F

FQSVF

GNSV70 FBL

FQSVF

GNSV75 FWW

FQSVF

GXSV65 R

FQSVF

GNSV75 RWW

FQSVF

GNSV70 RBL

FQSVF

Manufacturer:

General Electric Company

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:

Cysts
Turbidity

Asbestos
Lead
Mercury

Atrazine
Lindane
Benzene
VOCs

Alachlor
Atrazine
Benzene
Carbofuran
Carbon Tetrachloride
Chlorobenzene
Chloropicrin
2,4-D
DBCP
o-Dichlorobenzene
p-Dichlorobenzene
1,2-Dichloroethane
1,1-Dichloroethylene
cis-1,2-Dichloroethylene
trans-1,2-Dichloroethylene
1,2-Dichloropropane
cis-1,3-Dichloropropylene
Dinoseb

Endrin
Ethylbenzene
EDB
Haloacetonitriles (HAN)

Bromochloroacetonitrile
Dibromoacetonitrile
Dichloroacetonitrile
Trichloroacetonitrile

Haloketones (HK)

1,1-Dichloro-2-Propanone
1,1,1-Trichloro-2-Propanone

Heptachlor
Heptachlor Epoxide
Hexachlorobutadiene
Hexachlorocyclopentadiene
Lindane
Methoxychlor
Pentachlorophenol

Simazine
Styrene
1,1,2,2-Tetrachloroethane
Tetrachloroethylene
Toluene
2,4,5-TP (Silvex)
Tribromoacetic Acid
1,2,4-Trichlorobenzene
1,1,1-Trichloroethane
1,1,2-Trichloroethane
Trichloroethylene
Trihalomethanes (THMs)

Bromodichloromethane
Bromoform
Chloroform
Chlorodibromomethane

Xylenes

Microbiological Contaminants and Turbidity

Inorganic/Radiological Contaminants

Organic Contaminants

Do not use where water is microbiologically unsafe or with water of unknown quality, except that
systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

160 gal

Rated Service Capacity:

0.6 gpm

Rated Service Flow:

Advertising
This manual is related to the following products: