Warning, Performance data sheet – GE GNSV70RBL User Manual

Page 5

Advertising
background image

1

Influent challenge levels are average influent concentrations determined in surrogate qualification testing.

2

μg/L means Micrograms Per Liter.

3

Maximum product water level was not observed but was set at the detection limit of the analysis.

4

Maximum product level is set at a value determined in surrogate qualification testing.

5

Chemical reduction percent and maximum product water level calculated at chloroform 95% breakthrough point as determined in surrogate qualification testing.

6

The surrogate test results for heptachlor Epoxide demonstrated a 98% reduction. These data were used to calculate an upper occurrence concentration, which would produce a maximum product
water level at the MCL.

Organic Chemicals Reduced by Chloroform Surrogate Testing

Avg.

1

Max.

Contaminant

Influent (μg/L)

2

Effluent (μg/L)

2

Alachlor

50

1.0

3

Atrazine

100

3.0

3

Benzene

81

1.0

3

Carbofuran

190

1.0

3

Carbon Tetrachloride

78

1.8

4

Chlorobenzene

77

1.0

3

Chloropicrin

15

0.2

4

2,4-D

110

1.7

4

Dibromochloropropane (DBCP)

52

0.02

3

o-Dichlorobenzene

80

1.0

3

p-Dichlorobenzene

40

1.0

3

1,2-Dichloroethane

88

4.8

5

1,1-Dichloroethylene

83

1.0

3

cis-1,2-Dichloroethylene

170

0.5

3

trans-1,2-Dichloroethylene

86

1.0

3

1,2-Dichloropropane

80

1.0

3

cis-1,3-Dichloropropylene

79

1.0

3

Dinoseb

170

0.2

4

Endrin

53

0.59

4

Ethylbenzene

88

1.0

3

Ethylene Dibromide (EDB)

44

0.02

3

Haloacetonitriles (HAN):

Bromochloroacetonitrile

22

0.5

4

Dibromoacetonitrile

24

0.6

4

Dichloroacetonitrile

9.6

0.2

4

Trichloroacetonitrile

15

0.3

4

Testing was performed under standard laboratory conditions; actual performance may vary.
NOTE: Substances reduced are not necessarily in your water. Filter must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.

WARNING:

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst

reduction may be used on disinfected waters that contain filterable cysts.

Performance Data Sheet.

5

Advertising
This manual is related to the following products: