background image

The minimum spaces that must be maintained
between the appliance cooking surface and the
horizontal surface above the cooking top shall be:

A = 24 inches (600 mm) minimum when bottom
of wood or metal cabinet is protected by no less
than

1

/

4

-inch-thick flame-retardant millboard

covered with no less than No. 28 MSG sheet steel,
0.015-inch-thick stainless steel, 0.024-inch-thick
aluminimum, or 0.020-inch-thick copper.

There must always be a non combustible surface
between the top of the cooking surface (3) and the
bottom of the cabinet (2).

The building back wall (1) and building side walls
(4 / 5) must consist of non combustible material or
must be protected by no less than

1

/

4

-inch-thick

flame-retardant millboard covered with no less than
No. 28 MSG sheet steel, 0.015-inch-thick stainless
steel, 0.024-inch-thick aluminimum, or 0.020-inch-
thick copper.

1 Building back wall

2 Top building cabinet

3 Cooking surface

4 Building side wall

5 Building side wall

Caution! We do not recommend installation of the
appliance under a ventilator hood. Fire risk!

However, if the appliance is used exclusively with
our accessory griddle plate AM 060-000,
installation of the appliance under a ventilator hood
is possible. The minimun distance is 24 inches
(600 mm).

Installation next to a Gaggenau downdraft ventilator
is possible, please contact your Gaggenau dealer
who will provide you with more information.