Specifications – GE MDS 05-4558A01 User Manual

Page 17

Advertising
background image

14

MDS Mercury Series Startup Guide

05-4558A01, Rev. C

SPECIFICATIONS

GENERAL

Temperature Range:

–40° C to +70° C (–40° F to 158° F)

Humidity:

95% at +40° C (104° F); non-condensing

Primary Power:

10–30 Vdc

External Power Supply Options:

48 Vdc; 110–120/210–220 Vac

Typical Current Consumption (assumes 1 Watt RF Output):

Size (without mtg. hardware):

5.72 H x 20 W x 12.38 D cm
(2.25 H x 7.88 W x 4.88 D in.)

Mounting Options:

Flat surface brackets, DIN rail, 19” rack

Weight:

1kg / 2.2 lb.

Case:

Die Cast Aluminum

RADIO CHARACTERISTICS

GENERAL:
Frequency Band:

Mercury 900: 902–928 MHz
Industrial, Scientific & Medical (ISM) Band

Mercury 3650: 3650–3700 MHz
FCC Registered Band

TRANSMITTER:
RF Output @ connector:

Mercury 900: –30 to +30 dBm
Mercury 3650: 0 to 20 dBm
Increments of 1.0 dB, set

by user

Duty Cycle:

Continuous

Output Impedance:

50 Ohms

RECEIVER:
Type:

Double conversion superheterodyne

Sensitivity and Data Rate:

Dependent on modulation and bandwidth.
See

Reference Manual

Specifications.

Mode

DC Power

13.8 Vdc

24 Vdc

AP Transmit

25 W

1.8 A

1.0 A

AP Receive

8 W

579 mA

333 mA

RM Transmit

25W

1.8 A

1.0 A

RM Receive

6.5W

471 mA

270 mA