05-4558A01, Rev. C

MDS Mercury Series Startup Guide

7

NOTE:

Using

Configuration Scripts

under the

Maintenance/Tools

menu will aid in uniformly configuring multiple units. See the

Mercury Reference Manual

for details.

Step 5—Connect the Data Equipment

Connect Ethernet-compatible data equipment to the unit’s

LAN

port

(10/100 BaseT), or one of the serial ports, depending on the capability
of your transceiver.

Use a straight-through Ethernet cable to connect the

LAN

port

to a hub

or switch, and a crossover cable to connect it directly to an Ethernet
station (PC, PLC, RTU).

Step 6—Check for Normal Operation

This step verifies the proper operation of wireless communications
between an Access Point and its associated Remotes.

At All Units...

Observe the transceiver’s LED panel (See

Installation Setup Chart

)

for the proper indications. In a normally operating system, the radio
will typically become associated in about two minutes from start-up.

At the Access Point...

a. If the Access Point unit is the first unit you are installing, send

a

PING

command to it through the

LAN

port. This verifies basic

LAN

connectivity.

b. If you have already installed a Remote unit, try sending a

PING

to that unit through the Menu System

PING

utility or a device

connected to the unit on the same subnet.

At Remotes...

a. Look for the

LINK

LED to turn on and stay on. This indicates

the unit has successfully associated with the network’s Access
Point. (The association process may take up to 30 seconds.)

b. Check the

Starting Information

screen for the

Device Status

(also known as Connection Status). It will show one of the fol-
lowing:

Initializing

—This is the first phase after boot-up.

Advertising