See figure 4e), Installation – GSI Outdoors PNEG-1153 User Manual

Page 10

Advertising
background image

10

PNEG-1153 CALC-U-DRI Moisture/Matic/Manager

4. INSTALLATION

Figure 4E

Note: If there is more than 5/8" gap between the bottom pan and the outer edge of the

flighting, do not use a sensor in that location. Use another location, such as a
take-away auger.

(See Figure 4F).

2. Remove the flat bottom pan and mark the sensor cutout area at least one (1) pitch length

of the auger from the discharge area. This allows for good pickup of the grain when it leaves
the sensing area. Cut the sensor rectangle 1-11/16" x 5-11/16" with a saber saw (do not
torch cut) and check so the sensor block fits into it with the stepped edge.

(See Figure 4D).

3. Hold the pan up to the unit and mark the flighting where the sensor hole is located. Remove

the pan and mark the flighting about 3/8" away from marks just made, so the new marks
are six and one half (6-1/2)" apart.

Note: For seven (7)" flight or less, cut the flight to the shaft. Weld the auger flight to the

shaft at each end of the six and one half (6-1/2)" cutout marks, then cut out the six
and one half (6-1/2)" of flighting from the auger, leaving only the drive tube. For eight
(8)" or larger diameter flighting, one-half (1/2)" of flighting can be left as a ribbon
around the shaft in the cutout area.

(See Figure 4E).

4. Smooth all the rough edges from the cutout area.

Figure 4F

5/8" Max. Clearance
(Do not use if over 5/8")

Advertising