6. PRINTER INSTALLATION (OPTIONAL)

1. Disconnect all power (AC).

2. Remove the hole cover by removing the six (6) #8-32 screws holding it in.

3. Install the printer Wiring Decal 602L065 on the back of the inside door.

4. Remove the DMC 18 control board and open the dip switches 7 and 8 for your application.

See the dip switch chart on

Page 45

. Install the control board.

5. Install the black card guides (1EL0850) into the card holder. This is to hold the new card in

place.

6. Connect the wires coming from the green card connector to the black card connector

(1EL0854). There is a total of 11 wires. Refer to the Decal 602L065 mounted on the
Calc-U-Dri door and

Figure 6A

. Note colors and pin letters. This must be done correctly.

7. Mount the black card connector using two (2) 4 x 40 5/8" bolts, 4 x 40 nuts and star washer.

The numbered side of this connector will be visible when mounted correctly.

8. Connect the printer control cable to the black card connector. This cable will have a 25 pin

connector on one end. Refer to

Figure 6A

.

9. Install the five (5) volt power supply using two (2) 8 x 32 x 1/2" bolts. The locations is the

upper right of the back panel. The red and green wires will be coming out of the left edge
of the supply. Attach the violet and white wires to the two (2) post terminal two (2)" to the
left of the supply. Violet on the V terminal and white on the W terminal.

10. Attach the printer to the front panel with the five (5) #8-32 screws and nuts.