See figure 4j), Caution, Installation – GSI Outdoors PNEG-1153 User Manual

Page 12

Advertising
background image

12

PNEG-1153 CALC-U-DRI Moisture/Matic/Manager

4. INSTALLATION

SLOWLY ROTATE THE AUGER BY HAND ONE COMPLETE REVOLUTION. THE
FLIGHTING MUST MISS THE GAUGE COMPLETELY AND NOT RUB ON THE FILLER
PIECES. IF THERE ARE AREAS OF BINDING OR HITTING, CORRECT THE SITUATION
NOW.
!! DISCONNECT POWER !!

Figure 4J

7. Securing the sensor to the flat pan will require modified clamps. Cut the end off the clamp

and mount it with a self-drilling screw to the tapered side so the screw tip goes under the
filler pieces added earlier. Attach the screw end of the clamp or the other side with a
self-drilling screw. Have the length such that the screw is beside the sensor as show in

Figure 4I.

8. When installing the sensor, follow the instructions on the sensor decal for the correct

direction of grain movement.

Sensor Cut-Out for Flat Bottom Down Spout

1. When using a down spout, there must be a constant density of grain flowing over the sensor

for accurate readings. This flow must be independent of the total flow or velocity of the
stream of grain. To do this, the installation of the restrictor spout or flats angled to create a
funnel is recommended.

The sensor should be located in an accessible location, so it can be periodically inspected
for trash buildup.

2. Cut a hole in the bottom of the spout (1-11/16" x 5-11/16") and drill two 5/16" diameter holes

3-1/2" toward the discharge end and 5-1/2" apart as shown in

Figure 4K.

Use a saber saw

for the hole, not a torch. Remove burrs and check so the sensor block fits into the stepped
edge.

CAUTION

HOW TO INSERT GAUGE GAUGE AND FLIGHT PROPERLY INSTALLED