Servicing instructions, Replacing parts – Stovax Ceramica Coal Effect Stove Range Conventional Flue User Manual

Page 18

Advertising
background image

2.3

Loosen main injector nut on airbox and disconnect from

injector, see diagram 6, A.

2.4

Remove the 2 screws attaching burner to back of unit, see

diagrams 7. Carefully withdraw burner unit upwards and tilt

to remove the burner through door opening. Remove the 2

screws holding the heat shield in place.

Replace in reverse order checking all joints for leaks.

5

AR0943

18

3.1

Remove the burner module as described in Servicing

Section 2 above. Carefully cut the cable ties holding the

thermocouple to the pilot pipe. Remove the HT lead from

the electrode, undo the two retaining screws and remove

the pilot. See diagram 8.

3.2

When replacing the pilot ensure the thermocouple follows

its original route, i.e. along the pilot pipe. Attach the

thermocouple to the pipe with new cable ties.

3.3

Set the spark gap. See diagram 9.

SERVICING INSTRUCTIONS

REPLACING PARTS

3. PILOT UNIT

9

A

6

AR0498

A

7

AR0385

77

77

8

Advertising