14

Installation Instructions

265 VOLT ELECTRICAL CONNECTION OPTIONS

WARNING:

Connection of this 265 V AC product to a branch circuit
MUST

be done by direct connection in accordance with

the National Electrical Code. Plugging this unit into a
building mounted exposed receptacle is not permitted
by code.
These models must be installed using the appropriate
GE power supply kit for the branch circuit amperage
and the electrical resistance heater wattage desired.
Use the POWER CONNECTION CHART on page 16
to determine the correct kit required. One of the
following installation methods (A or B) must be used.

A. FOR SUBBASE INSTALLATION

Electrical subbase kits are available to provide a flexible
enclosure for direct connection.

The instructions provided with the selected subbase kit
must be carefully followed. It is the responsibility of the
installer to ensure the connection of components is
done in accordance with these instructions and all
electrical codes.

Branch Circuit and

Proper GE

Power

Unit Amperage Rating

Subbase Kit

Supply Kit

15

RAK204E15

RAK5172

20

RAK204E20

RAK5202

30

RAK204E30

RAK5302

B. FOR DIRECT CONNECT

INSTALLATION

If an electrical subbase is not used, direct connection to
branch circuit wiring inside the provided junction box
must be done in accordance with the following steps.
Order the following Kit for 265-volt direct connection
as required:

Proceed to the “MAKE ELECTRICAL CONNECTION
TO THE UNIT” section.

Branch Circuit and

Power

Unit Amperage Rating

Supply Kit

15

RAK5157

20

RAK5207

30

RAK5307

NOTE:

Order Kit RAK4002A to enable a quick

disconnect inside the junction box.