GE 263 User Manual

Page 29

Advertising
background image

Level II Programming

29

Rev A

The calendar override days between regeneration must be set to zero
to enable regeneration on specific days.

Setting Backwash Days (263 filter only)

The 263 filter controller can be programmed to regenerate on an elapsed
time period (calendar override) or by the day of the week. If you would like
to regenerate on specific days select a 0 (zero) for the calendar override
setting, the 263 filter will prompt you to select the days of the week in
which you would like the unit to regenerate/backwash. For example, the
unit could be programmed to regenerate every Monday, Wednesday and
Friday.

Setting the Salt Amount (268 softener only)

Is selected by the system model number. Your Ultramax Water Treatment
Dealer enters the model numbers based on the specific application
requirements.

Setting Capacity
Softener Default Capacity Setting
The default capacity setting is accurately calculated when the model
number is entered by the factory. The capacity can be changed to
operate "custom systems". Contact your Ultramax Water Treatment
Dealer before adjusting the capacity setting. Default capacities are
shown in Table 1.

Filter Capacity
Filter capacity is set in gallons or cubic meters. It is programmable
from 100 to 14000 gallons or 1 to 140 cubic meters of capacity. Press
the SET button and the digits will begin flashing. Change the capacity
by using the up and down arrows to adjust the setting. To accept the
setting, press the SET button.

Setting the Hardness (conditioner only)
Hardness is set in grains per gallon (gpg) or parts per million (ppm) and
should be programmed to the total hardness level of the incoming
water supply. Press the SET button to make the display flash. Use the
UP and DOWN buttons to adjust the hardness setting. Press the SET
button when the desired setting has been reached.

Setting the Language

NOTE:

Regeneration on specific day is used to provide regeneration

when water demands are not steady. Example: If the weekdays have
low usage and the weekend is high, then regeneration every three days
will not meet the requirements.

NOTE:

(Conditioners only) A different model number must be selected

to change the default capacity and salt dosage.

Advertising
This manual is related to the following products:

268