Placing Conditioner Into Operation

Rev A

Placing Conditioner Into Operation

Conditioner and Filter Start-Up

After you have performed the previous initial power-up steps, you will
need to place the conditioner into operation. Follow these steps carefully,
as they differ from previous Autotrol valve instructions.

1. Remove the cover from the valve. Removing the cover will allow you to

see that the camshaft is turning, and in which cycle the camshaft is
currently positioned.

2. With the supply water for the system still turned off, position the

bypass valve to the “not in bypass” (normal operation) position.

3. Press and release the REGEN button on the controller. The scrolling

text on the display will show "DELAYED REGENERATION". Press UP to
navigate to "IMMEDIATE REGENERATION".

4. Press and release SET and UP to begin regeneration. The display will

show eight LEDs moving from left to right on the banner display
indicating that the motor is running. Additionally, the display will show
the total regeneration time remaining.

Pressing SET when the motor has stopped displays the cycle
description and cycle time remaining.

5. Press and release SET and UP simultaneously to advance to each

cycle.

6. Advance the control to the Backwash. See below for the cycle

sequences.

7. Fill the media tank with water.

A. While the controller is in cycle (Backwash), open the water supply

valve very slowly to approximately the 1/4 open position.

NOTE:

The control valve can be started-up even if power is not yet

available to the controller. The valve must be connected to the water
supply. The motor can be unmounted from the valve, and the camshaft
can be indexed manually counterclockwise by hand. This will allow the
tank to be filled and allows regenerant draw to be tested.

Function

Display Text (268)

Display Text (263)

Treated Water

Ultramax (268)

Ultramax (263)

Regeneration

Backwash
Brine Draw/Slow Rinse
Pause - Please Wait
Fast Rinse 1
Backwash 2
Fast Rinse 2
Brine Tank Refill

Backwash