System troubleshooting – GE 263 User Manual

Page 40

Advertising
background image

40

Troubleshooting

Rev A

System Troubleshooting

Problem

Possible Cause

Solution

1. Brine tank

overflow.

a. Uncontrolled brine refill flow rate.
b. Air leak in brine line to air check.

c. Drain control clogged with resin

or other debris.

a. Remove brine control to clean ball and seat.
b. Check all connections in brine line for leaks.

Refer to instructions.

c. Clean drain control.

2. Flowing or

dripping water at
drain or brine line
after
regeneration.

a. Valve stem return spring weak.
b. Debris is preventing valve disc

from closing.

a. Replace spring. (Contact dealer.)
b. Remove debris.

3. Hard water

leakage after
regeneration.

a. Improper regeneration.

b. Leaking of external bypass valve.
c. O-ring around riser pipe

damaged.

d. Incorrect capacity.

a. Repeat regeneration after making certain

correct regenerant dosage was set.

b. Replace bypass valve. (Contact dealer.)
c. Replace O-ring. (Contact dealer.)

d. Verify appropriate regenerant amount and

system capacity. (Contact dealer.)

4. Control will not

draw brine.

a. Low water pressure.

b. Restricted drain line.
c. Injector plugged.
d. Injector defective.
e. Valve disc 2 and/or 3 not closed.

f. Air check valve prematurely

closed.

a. Make correct setting according to

instructions.

b. Remove restriction.
c. Clean injector and screen.
d. Replace injector and cap. (Contact dealer.)
e. Remove foreign matter from disc and check

disc for closing by pushing in on stem.
Replace if needed. (Contact dealer.)

f. Put control momentarily into brine refill.

Replace or repair air check if needed.
(Contact dealer.)

5. Control will not

regenerate
automatically.

a. AC adapter or motor not

connected.

b. Defective motor.

a. Connect power.

b. Replace motor. (Contact dealer.)

6. Control

regenerates at
wrong time of
day.

a. Controller set incorrectly.

a. Correct time setting according to

instructions.

7. Valve will not

draw brine.

a. Low water pressure.
b. Restricted drain line.
c. Injector plugged.
d. Injector defective.
e. Air check valve closes

prematurely on brine pickup
tube.

a. Set pump to maintain 20 psi at softener.
b. Change drain to remove restriction.
c. Clean injector and screen.
d. Replace injector. (Contact dealer.)
e. Put control momentarily into brine/slow

rinse. Replace or repair air check if needed.
(Contact dealer.)

8. System using

more or less salt
than regenerant
setting.

a. Foreign matter in valve causing

incorrect flow rates.

a. Remove brine control and flush out foreign

matter. Advance control to brine/slow rinse,
to clean valve (after so doing position
control to "fast rinse” to remove regenerant
from tank).

Advertising
This manual is related to the following products:

268