Warning, Djustments – Genie 3681036666 User Manual

Page 7

Advertising
background image

7

LOCATED
UNDER
LIGHT
COVER

OPEN
FORCE

CLOSE
FORCE

B OPEN ADjUSTMENT

On front panel of Power Head find adjusting

screw marked “OPEN” (Figure 9) .

Gently turn screw counterclockwise until it stops .

Very little force is required to turn

adjusting screw .

Press Wall Console to open garage door .

Observe if door stops at “OPEN” limit switch .

If door is fully open—adjustment is finished .

If door stops but is not fully open,

a . Measure distance between bottom of

door and top of door opening .

b . Move “OPEN” Limit Switch that same

distance toward Power Head .

If door stops before reaching the “OPEN”

Limit Switch

a . Slightly increase OPEN Force

setting (clockwise) .

If door fails to move, see Troubleshooting

Section, pages 10 & 11 .

C Run Door Opener

Cycle opener a few times to double check

settings . Repeat adjustment steps as necessary .

WARNING

• The garage door opens rapidly, and can cause serious

injury or death .

• Keep the path clear.
• Position the ladder to the side of the Power Head so it

is clear of all moving parts of the Opener and the door .

• Set the door Opener to use the minimum force needed

to open the door .

Coarse Setting of Limit Switches

A Setting Close Limit Switch

Check that Carriage Assembly is disengaged.

With garage door fully closed, slide Close Limit Switch

until it is aligned with the center of the

Carriage Assembly .

Tighten Set Screw. Do Not over-tighten.

B Setting Open Limit Switch

Manually open garage door to full open position.

Slide Open Limit Switch until it is aligned with the center

of the Carriage Assembly .

Tighten Set Screw. Do not over-tighten.

Re-engage Carriage Assembly.

Setting Force Controls and Final Adjustment of

Limit Switches

A CLOSE ADjUSTMENT

On front panel of Power Head find adjusting screw

marked “CLOSE” (Figure 9) .

Gently turn screw counterclockwise until it stops .

Very little force is required to turn adjusting screw .

Press Wall Console to close garage door .

Observe if door stops at “CLOSE” limit switch .

If door is fully closed—adjustment is finished .

Go to “OPEN” Adjustment .

If door stops but is not fully closed,

a . Measure distance between bottom of door

and floor .

b . Move “CLOSE” Limit Switch that same distance

toward door .

If door stops and/or reverses before reaching the

“CLOSE” Limit Switch

a . Slightly increase CLOSE Force setting (clockwise) .

If door reverses after contacting floor, move Limit

Switch toward Power Head .

If door fails to move, check Safe-T-Beam® System . See

Troubleshooting Section, pages 10 and 11 .

WARNING

• The garage door opens rapidly, and can cause serious

injury or death .

• Keep the path clear.
• Position the ladder to the side of the Power Head so it is

clear of all moving parts of the Opener and the door .

• Set the door Opener to use the minimum force needed

to open the door .

NOTE

Little effort is required to turn the Force Adjusting Knobs .
If the door stops moving while opening or closing, adjust the

Open Force or Close Force Controls slightly clockwise (to

slightly increase the force) and retry the step .
The Open Force and Close Force Controls are to be set to the

minimum force necessary to ensure the door smoothly opens

and closes completely .
Ensure the Carriage Assembly is engaged and is between the

two Limit Switches before operating the Opener .

Figure 9 Making Force Adjustments
(Located Lower Right Corner) .

C

h

S

et

l

imit

S

witCheS

aND

f

oRCe

C

oNtRolS

a

DjuStmeNt

1:

a

DjuStmeNtS

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

Advertising